Mitsubishi Electronics MSZ-A18YV Air Conditioner User Manual


 
12
INSTALLATION, RELOCATION AND INSPECTION
Installation place
Avoid installing the air conditioner in the following places.
Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.
Where there is much machine oil.
Salty places such as the seaside.
Where sulfide gas is generated such as a hot spring.
Where oil is splashed or where the area is filled with
oily smoke.
Where there is high-frequency or wireless equipment.
CAUTION:
Earth the unit.
Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.
Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places,
etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
Inspection and maintenance
When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
dust, etc.
It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.
Operating sound considerations
Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.
If an abnormal sound is heard during operation, consult your dealer.
Relocation
When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and
work are required.
WARNING:
Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
If you have any questions, consult your dealer.
WARNING:
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will
be generated.
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
WARNING:
The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc.
Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.
Guaranteed operating range
Indoor Outdoor
Upper limit
32°C DB 43°C DB
Cooling
23°C WB
Lower limit
21°C DB -10°C DB
15°C WB
Upper limit
27°C DB 24°C DB
Heating
18°C WB
Lower limit
20°C DB -10°C DB
-11°C WB
To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.
wall, etc.
Inverter-type
fluorescent lamp
Keep a space
to prevent the
picture
distortion or
the noise.
1 m
or more
Radio
100 mm or
more
Well-
ventilated
dry place
500 mm or
more
TV
Cordless
phone or
Portable
phone
3 m
or more
1 m
or more
* The required space depends on the type of outdoor unit.
The installation location of the outdoor unit should be at least
3 m away from the antennas for TV sets, radios, etc. In areas
where the reception is weak, provide greater space between
the outdoor unit and the antenna of the affected device if op-
eration of the air conditioner interferes with radio or TV recep-
tion.