Mitsubishi Electronics MSY-GE12NA Air Conditioner User Manual


 
21
OPERATION INDICATOR
No.
Abnormal
point
Operation indicator lamp Symptom Condition
Remedy
1
MXZ type
Operation
mode
setting
Upper lamp lights and lower lamp ashes.
2.5-second OFF
Outdoor unit
operates but
indoor unit does
not operate.
The operation mode of the each indoor unit
is differently set to COOL (includes DRY) and
HEAT at the same time, the operation mode
of the indoor unit that has operated at rst has
the priority.
Unify the operation mode.
Refer to outdoor unit service
manual.
9-5. TROUBLE CRITERION OF MAIN PARTS
MSZ-GE06NA MSZ-GE09NA MSZ-GE12NA MSZ-GE15NA MSZ-GE18NA
MSY-GE09NA MSY-GE12NA MSY-GE15NA MSY-GE18NA
Part name Check method and criterion Figure
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12, RT13)
Measure the resistance with a tester.
Refer to 9-7. "Test point diagram and voltage", "2. Indoor electronic control
P.C. board", for the chart of thermistor.
Indoor fan motor (MF)
Check 9-6.
Vane motor (MV)
Measure the resistance between the terminals with a tester.
(Temperature: 50 - 86°F (10 - 30°C))
Color of the lead wire Normal
RED - BLK 223 - 268 Ω
BLK
BLK
RED
BLK
BLK
ROTOR