Mitsubishi Electronics MCF-D24VD Air Conditioner User Manual


 
En-7
• OPERATING INSTRUCTIONS •
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated. • Is the breaker turned on?
• Is the power supply plug connected?
• Is the ON timer set?
Page 5
The unit cannot be operated
for about 3 minutes when
restarted.
• This protects the unit according to instruc-
tions from the microprocessor. Please
wait.
The fan stops during the DRY
operation.
• In DRY operation, the unit operates using
the same refrigerant circuit as in COOL
operation. DRY operation time has to be
reduced in order to lower humidity without
much room temperature decreasing. So
the compressor sometimes stops, and at
the same time the indoor fan stops. This
prevents water condensed on the heat
exchanger from evaporating again.
Mist is discharged from the air
outlet of the indoor unit.
• The cool air from the unit rapidly cools mois-
ture in the air inside the room, and it turns
into mist.
The swing operation of the
HORIZONTAL VANE is
suspended for a while, then
restarted.
• This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
The air fl ow direction changes
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.
• When the unit is operated in COOL or DRY
mode, if the operation continues with air
blowing down for 0.5 to 1 hour, the direction
of the air fl ow is automatically set to position
(1) to prevent water from condensing and
dripping.
The unit starts operation by
itself when the main power
is turned on, though it isn’t
operated with the remote
controller.
• These models are equipped with an auto re-
start function. When the main power is turned
off without stopping the unit with the remote
controller and is turned on again, the unit
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shutoff of the main power.
Refer to “Auto restart function” page 4 .
Outdoor Unit
Water leaks from the outdoor
unit.
• During COOL and DRY operations, pipe or
pipe connecting sections are cooled and this
causes water to condense.
Symptom Explanation & Check points
Remote controller
The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the
remote control signal.
• Are the batteries exhausted? Page 3
• Is the polarity (+, -) of the batteries correct?
Page 3
• Are any buttons on the remote controller of
other electric appliances being pressed?
Does not cool
The room cannot be cooled
suffi ciently.
• Is the temperature setting appropriate?
Page 4
• Is the fan setting appropriate? Please
change fan speed to higher setting.
• Are the fi lter clean?
Page 6
• Is the fan or heat exchanger of the indoor unit
clean?
• Are there any obstacles blocking the air inlet
or outlet of the indoor or outdoor unit?
• Is a window or door open?
• When a ventilation fan or a gas cooker is
used in a room, the cooling load increases,
resulting in an insuffi cient cooling effect.
• When the outside temperature is high, the
cooling effect may not be suffi cient.
Airfl ow
The air from the indoor unit
smells strange.
• Are the fi lter clean? Page 6
• Is the fan or heat exchanger of the indoor unit
clean?
• The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it
out with the air.
Sound
Cracking sound is heard. • This sound is generated by the expansion/
contraction of the front panel, etc. due to
change in temperature.
The sound as burbling is
heard.
• This sound is heard when the outside air is
absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
Mechanical sound is heard
from the indoor unit.
• This is the switching sound in turning on/off
the fan or the compressor.
The sound of water fl owing
is heard.
• This is the sound of refrigerant or condensed
water fl owing in the unit.
In the following cases, stop using the air conditioner and consult your
dealer.
When water leaks or drips from the indoor unit.
When the upper operation indicator lamp blinks.
When the breaker trips frequently.
The remote control signal is not received in a room where an electronic ON/OFF
type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
When an abnormal sound is heard.
OPERATING INSTRUCTIONS
WHEN YOU THINK THAT TROUBLE HAS OCCURRED