Mistral MEC1R Humidifier User Manual


 
5
Nature: Nature settings provide a soft and
comfortable environment with a choice of
high, medium or low fan speeds.
Sleep: The sleep function uses the natural fan type
and slowly lowers the speed of the Evaporative
Cooler before finally turning it off altogether.
At high speed, the Evaporative Cooler will operate
at the highest speed for 30 minutes, the medium
speed for 30 minutes and the low speed for 30
minutes before turning off.
At medium speed, the Evaporative Cooler will operate
at the medium speed for 30 minutes and the low
speed for 30 minutes before turning off.
At low speed, the Evaporative Cooler will operate
at low speed for 30 minutes before turning off.
Timer
The timer settings are for 0.5, 1, 2 or 4 hours. When
the timer is set, the indicator “LED” will show it is in
use. Press it once and the 0.5 indicator will illuminate
.
Press it again and the 1 indicator will illuminate (having
both the 0.5 and the 1 hour indicators lit indicates the
timer is set for 1.5 hours). Pressing the timer button
four times in total will set the timer for 7.5 hours.
When none of the timer lights are lit, the timer is not
set.
Flow
Press this key to turn on or off the automatic vertical
louvre function. The direction can also be adjusted
by using the manual horizontal louvre.
Cool Air
Press this key to start and stop the flow of cool air.
Always disconnect electrical appliances before
cleaning them.
Never spray with liquids or submerge the Evaporative
Cooler in water or any other liquid.
Note: If the cordset of this appliance becomes
damaged, discontinue use. Repairs should be
undertaken only by a qualified technician.
Cleaning the Dust-Proof and Evaporated
Nets
To clean the dust-proof and evaporated nets, ensure
the Evaporative Cooler is turned off and disconnected
from the power outlet.
Press the dust-proof net and pull it out of the main unit.
Twist off the two screws on the back cover and take
them out. Twist off the two screws between the
evaporated net holder and the wind channel, then
remove the evaporated net from its holder.
Clean both using a damp sponge or cloth.
Cleaning the Pump
Before cleaning the pump, ensure the Evaporative
Cooler is turned off and disconnected from the power
outlet, remove the rubber plug from the back of the
unit and drain the water. Remove the back cover,
twist off the two screws of the pump and remove
the rotor.
Clean it with a damp sponge or cloth and dry
thoroughly before reinstalling it by reversing the
above procedure.
Note: If the Evaporative Cooler stops working
efficiently, drain the water from it and operate
it on normal fan type at high speed for 1-2
hours to allow the evaporated net to dry.