Middleby Marshall KIT P/N 36939 Thermostat User Manual


 
INSTALLATION INSTRUCTIONS
This manual provides instructions for conversion:
from to
Analog Temperature Controller (A), PN 28071-0012
(without high-limit and cool down function)................................
Analog Temperature Controller (A), PN 28071-0018
(with high-limit and cool down function).....................................
Digital Temperature Controller (B), PN 28071-0027
(with blue plastic face)................................................................
Digital Temperature Controller (C), PN 28071-0028
(with gray rubberized face and no symbols)..............................
Digital Temperature Controller (D), PN 28071-0028
(with gray rubberized face and symbols)................................... to (F) Digital Temperature Controller, PN 36056
Digital Temperature Controller (D), PN 30871
(with gray rubberized face set for “high voltage”;
CE & 360WB-70).......................................................................
Digital Temperature Controller (D), PN 32571
(360EWB modulating system with gray rubberized face
set for “high voltage”)................................................................
Digital Temperature Controller (E), PN 36021
(gray metal face with silver boarder multi-voltage ready
[100 - 260 V]; for all models including CE)................................
NOTE
The replacement temperature controller, PN 36056, replaces all
former model temperature controllers. Therefore, this control is
designed to operate on all old and current model Middleby
Marshall ovens.
A CURRENT VERSION THERMOCOUPLE IS
REQUIRED FOR PROPER OPERATION OF THE LATEST
TEMPERATURE CONTROLLER P/N 36056.
SEE THE
WIRING SECTION OF THESE INSTRUCTIONS FOR DETAILS.
1
PN 28071-0028
PN 28071-0028
PN 30871
PN 32571
PN 28071-0027
PN 36056
CAUTION
When installing the controller, PN 36056, into a model
360EWB, the control must be programmed to operate on
the mA output terminals 15 and 16. Refer to Instructions.
A
B
C D
E
F
PN 28071-0012
PN 28071-0018
PN 36021
SET PT
HEAT ON
SET PT
ACTUAL
TEMP
SP
LOCK
OVER TEMP
250 F
SP LOCK
500 F