Mercury SR-10K Home Security System User Manual


 
Doc. 10107-0007 Rev 1.04
Page 18
Mercury Security Corporation, © 2005 SR-10K
1.4 [36]
2.9 [74]
3.25 [83]
2 X Ø0.18 [4.5]
HOLES
2.0 [50]
5.5 [140]
1.3 [33]
3.3 [84]
2.6 [66]
Reader and Interface Dimensions
Reader to Interface Connection:
Connect the Reader to the Interface
Module using the straight 6-conductor
modular cable. DO NOT use cross-
over cable. Maximum distance
between reader and interface is 500
feet using 22AWG wires.
6-COND. STRAIGHT
Typical Wiring Configuration
Communication Wiring: Maximum total cable length - 4,000 ft [1,200 m], 24 AWG
JUMPER SETTING
Set each interface to unique address. Install RS-485 termination jumper, J4, on the first and last units only.
SR−10K SR−10K PRINTER INTERFACE
TO ADDITIONAL
SR−10K
(DISCONTINUED)
Exit Request
Door Contact
Strike
Forced Open,
Held Open
Alarm Buzzer
I1
I1
I2
I2
GND
+
12V
C
NC
NO
NO
C
NC
K1
K2
J2 Jumpers