Master Lock E72 Door User Manual


 
Factory Code
*
9991234
PIN
Initialize Great Grand Master
Page 2
IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.
3 to 6 Alpha-Numeric
#
Level: Master
When the Great Grand Master (GGM) is entered it has the two components that are found in all codes.
1. User ID (UID) 3 to 4 DIGITS
2. Pin Number (PIN) 3 to 6 DIGITS/ALPHA/MULTIPLE KEY DEPRESSIONS
3. UID and PIN have a MAXIMUM TOTAL LENGTH of 9 DIGITS.
The length of the GGM’s UID and PIN determine the length of all FUTURE MANAGEMENT and USER
CODES. This allows the GGM to set the overall level of security for the lock at the time of initialization.
User Defined (3-4 Digits)
User ID
ENTRIES VISUAL / AUDIO
#
Note
UID MUST be DIGITS ONLY.
PIN CAN be ALPHA/NUMERIC/MULTIPLE KEY DEPRESSIONS.
No group number is given to the GGM.
Only ONE GGM per lock.
1.
2.
3.
Function 12 Set Time
Page 3
IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.
Valid User Code
Level: Master
TIME MUST BE SET PRIOR TO ACTIVATING SCHEDULING.
This function SETS the INTERNAL TIME of the LOCK. The lock uses military time and is automatically
updated when the upload/download module (IDT) is used. Ex. 1530=3:30 p.m.
Mgmt. Defined Hours Minutes
Time
*
ENTRIES VISUAL / AUDIO
Function Number
2
*
1
Note
TIME MUST BE SET PRIOR TO ACTIVATING SCHEDULING.
The Default for this function is DAYLIGHT SAVINGS TIME ENABLED.
To DISABLE DAYLIGHT SAVINGStime, press “0” as the LAST DIGIT of the time entry.
Ex. 18380 = DISABLED 1838= ENABLED
For Military Time Conversion Chart, see page 30.
ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.
#
See Note
Exit
*
1.
2.
3.
4.