9
099565
To Stop Heater
WARNING ICON G 001
CAUTION
Never unplug heater while heater is running. Heater must go
through purge cycle. The purge cycle cools the combustion
chamber. Damage to heater can occur if combustion chamber is
not cooled. Do not restart heater until purge cycle is complete.
1. Drain all fuel from fuel filters, fuel lines, and pump (see Fuel Filters [Tank Fuel
Filter], page 17).
2. Clean and flush fuel filter and canister attached to fuel pump (see Fuel Filters
[Pump Fuel Filter], page 17).
3. Remove drain plug and drain fuel tank.
4. Replace drain plug.
5. Add one gallon (four liters) of clean kerosene to fuel tank.
6. Attach fuel cap.
7. Move the heater forwards and backwards to stir fuel.
8. Remove drain plug and drain fuel tank.
9. Replace drain plug.
10. Add two gallons (eight liters) of clean kerosene or No. 1 fuel oil to fuel tank.
11. Replace fuel cap.
12. Operate heater for 5 minutes (see Operation, page 8).
13. Stop heater and let cool completely.
14. Remove drain plug and drain fuel tank.
15. Replace drain plug.
16. Properly dispose of old and dirty fuel.
17. Store heater in a dry location. Make sure storage place is free of dust and
corrosive fumes.
IMPORTANT:
Do not store kerosene over summer months for use during next
heating season. Using old fuel could damage heater.
STORAGE
To Restart Heater
WARNING ICON G 001
CAUTION
Do not restart heater until purge cycle is finished. The purge
cycle cools the combustion chamber.
1. Wait until purge cycle is finished after stopping heater.
2. Repeat steps under To Start Heater, page 8.
1. Turn thermostat dial to lowest temperature setting. This will cause heater
flame to go out. The motor will continue to run during the purge cycle. This
allows the fan to cool the combustion chamber. When the purge cycle is
finished, the motor will stop. Do not unplug heater until purge cycle is
finished.
2. Unplug extension cord from outlet.
3. To temporarily stop heater, set thermostat at a temperature lower than air
around heater. Heater will cycle back on if air temperature around heater
matches thermostat setting.
OPERATION
Continued