3 © MARMITEK
INSTALLATION
1. Register all wireless devices to the ProGuard800 control panel as explained in
the ProGuard800 installation manual.
2. On the control panel, define the detection devices that are intended to transmit
via the repeater as follows:
• From the Programming menu, select Devices, Zones [911].
• Select the zone you want to program (1-32).
• From the zone’s sub-menu, select Repeater [#9].
• Select “Use Repeater”.
Note: It is not necessary to define, at the control panel, the keypads and
keyfobs that are registered to the repeater.
3. Open the RP835’s plastic housing. To do so, remove the two cover screws
and lift the front cover away from the base.
4. Connect the antenna provided to the antenna connector.
5. Connect the backup battery pack to the Battery connector.
6. Connect a 9VAC or 12VDC transformer to the Power Input terminal block
(polarity is not important).
7. All registration and test functions, described in the following sections, are
performed from the LCD Programming Keypad (PK836) shown in Figure 3.
Antenna
Connecto
r
Programming
Ke
yp
ad
(
PK836
)
Lowe
r
Mounting
Hole
Lower
Mounting
Hole
LED Indicato
r
Receive
r
Tamper
Switch
AC Powe
r
Protection Fuse
Uppe
r
Mounting
Hole
Transmitte
r
Flash
Programming
Power Inpu
t
Terminals
Wiring
Hole
Backup
Battery Pack
Batter
y
Connecto
r
Figure 2: RP835 (cover removed)