Marmitek MS8000 Home Security System User Manual


 
NOTE:
Instruct the person who’s number has been entered
to give the confirmation 0 just after the beep(s).
Since telephone answering machines or voice mail
facilities will not generate the confirmation, these
will be ignored. It is recommended to do a test with
the people involved in order to let everyone get
aquatinted with the system.
12. TROUBLESHOOTING:
1. The base station does not react at all, the green
indicator is not on:
Check the power supply and/or the replace the
back-up battery.
2. The telephone dialler does not dial out:
Check that the telephone plug is connected
properly
Check that the telephone outlet is responding
to a normal analog telephone.
3. False alarms:
Reposition the HomeGuard, away from heating
elements, direct sunlight, etc.
Check that no pets can trigger the alarm.
4. Limited range of the remote (option):
Check the condition of the battery and replace
the battery if required.
Check if no other devices interfere on the same
frequency e.g. wireless headphones etc.
5. PIR or siren do not respond:
Check that PIR or SIREN has been activated.
6. The sensor HomeGuard does not react to the
remote:
Follow the registration procedure in order to
lock in the remote.
Check that the indicator on the remote comes
on. If not, replace the battery
7. Any other malfunction:
Disconnect the HomeGuards from mains and
back-up battery. This will reset the HomeGuard.
Re-install the HomeGuard according to the
instruction manual.
Do not open the power supply or
HomeGuard. No serviceable parts inside!
HOMEGUARD MS8000 7