Marmitek MS8000 Home Security System User Manual


 
has been entered by more than one HomeGuard, you can
transmit an extra audible signal with the pre-recorded
message in order to identify the HomeGuard calling. The
factory default is one beep at the end of the message.
To change the number of beeps (1, 2 or 3):
1. Enter your PIN
2. Press 4 on the keyboard
3. Press 1, 2 or 3 for the required number of
identification beeps.
7. REGISTERING REMOTE
CONTROLS (HANDSHAKE)
HomeGuard can be remotely controlled by up to
4 radio remotes (1 piece KR21 supplied). For securi-
ty reasons, each remote selects a unique code (1
out of 65.536) after the battery has been installed.
Before using HomeGuard, the base station has to
learn this specific code from each remote:
1. Enter your PIN (Personal Identification Number).
Factory default is [0000] see (5): You will hear
three high tones and one low tone as con-
firmation. The green indicator starts flashing.
2. Press 1 on the keyboard of the HomeGuard: One
high tone is given for confirmation.
3. Press the ARM button on your remote: One low
tone is given for confirmation.
4. Repeat step 1-3 for a second up to fourth
remote if required.
5. Press any button on your HomeGuard keyboard
to finalise the registration procedure: One short
low tone is given and the green indicator stops
flashing.
If no successive commands are entered within a
period of 15 seconds, the base station returns to
normal operation. To restart the registration you
start the procedure from step1.
8. DELAY ARM
The alarm mode may be activated by either the
remote control or by the keyboard.
If the remote control is used, the HomeGuard arms
and disarms instantly.
If you require a delay, in order to allow yourself to
leave or enter the room before arming or disarming
the HomeGuard, you may set the HomeGuard to
Delay Arm:
1. Enter your PIN (Personal Identification Number).
Factory default is [0000]: You will hear three
high tones and one low tone as confirmation.
The green indicator starts flashing.
2. Press 7 on the keyboard of the HomeGuard: One
low tone is given for confirmation.
3. Press [ * ] for Delay Arm or # for Instant Arm:
One tone is given for confirmation and the indi-
cator stops flashing.
9. SIREN
Your HomeGuard is equipped with a built-in siren.
This siren will frighten intruders so they’ll leave the
house.
If you require a so-called silent alarm (without siren),
you can change the factory default:
1. Enter your PIN (Personal Identification Number).
Factory default is [0000]: You will hear three
high tones and one low tone as confirmation.
The green indicator starts flashing.
2. Press 3 on the keyboard of the HomeGuard: One
low tone is given for confirmation.
3. Press [ * ] for Siren On or # for Silent Alarm: One
tone is given for confirmation and the indicators
stops flashing.
HOMEGUARD MS8000 5