Marley Engineered Products B Fan User Manual


 
Horiz. Air
Discharge Wt.
kW Voltage and Phase (Ft.) BTUH CFM (Lbs.) A B C D E
3
208/240V-1 or 3Ø
28 10,236 700 127 19-1/8 23-7/8 21 3-1/2 13-5/8
480/575V-3Ø
5
208/240V-1 or 3Ø
28 17,060 700 127 19-1/8 23-7/8 21 3-1/2 13-5/8
480/575V-3Ø
7.5
208/240V-1 or 3Ø
32 25,590 840 133 19-1/8 23-7/8 21 3-1/2 13-5/8
480/575V-3Ø
10
240V-1 or 3Ø
32 34,120 840 138 19-1/8 23-7/8 21 3-1/2 13-5/8
208/480/575V-3Ø
15
208/240/480V
47 51,180 1450 150 25 27-7/8 21 4-13/32 17-5/8
575V-3Ø
18 240V-3Ø 43 61,420 1400 165 25 27-7/8 21 4-13/32 17-5/8
20 480/575V-3Ø 43 68,240 1400 165 25 27-7/8 21 4-13/32 17-5/8
25 480/575V-3Ø 54 85,300 2330 200 32-1/8 31-7/8 21-3/4 5-1/2 21-5/8
30 480/575V-3Ø 54 102,360 2330 200 32-1/8 31-7/8 21-3/4 5-1/2 21-5/8
35 480/575V-3Ø 54 119,420 2330 200 32-1/8 31-7/8 21-3/4 5-1/2 21-5/8
Class I
Group C & D, Div. 1 & 2
Class II
Groups E, F & G
T3B - 165°C (329°F)
Table A  Specifications
5200-2474-000
161-302421-006
MAY, 2002
DATE
SALES
REFERENCE
INSTALLATION, OPERATION
RENEWAL PARTS IDENTIFICATION
X Series (Model B)
Explosion Proof
Heater
SAVE THESE INSTRUCTIONS
11-1/16
C
A
D
B
A
E
2
2
Overall Dimensions
(In.)
5/8 UNC Tapped
Mounting Hole
Locations