Marley Engineered Products 994 Fan User Manual


 
Inspect contents of carton for possible shipping and handling damage. The blades are a carefully matched set. If one or more
blades from a carton has been damaged, arrange to have all the blades replaced.
BLADES ARE PACKED AS A MATCHED SET AT THE FACTORY IN ORDER TO ENSURE SMOOTH FAN OPERATION.
If more than one fan is being installed, be careful to attach blades removed from one carton to the same fan.
DO NOT MIX BLADES FROM DIFFERENT CARTONS.
FAN NO. OF FAN BLADE NO. OF CARTONS MINIMUM DISTANCE FAN USE CONTROL
MODEL SERIES BLADES SPAN “C” FAN SHIPPED IN DIM. A DIM. B WEIGHT (LB.) MODEL NO.
994 GILLESPIE 5 52 1 13.00 12.5 20 9290
994PF PORCH FAN** 5 52 1 13.00 12.5 20 9290*
* Installer must take adequate precautions to insure water does not enter installation.
Refer to Marley Engineered Products Sales Literature for Light Kit Models available.
WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with the controls listed in Chart 1.
Use only Light Kits marked “Suitable for use in Damp locations” with Damp location fans.
A
B
C
CHART 1
** Damp Location Fan
994 Series
Ceiling Fans
Read Carefully - These instructions are written to help you prevent difficulties that might arise during installation. Studying
the instructions first may save you considerable time and money later. Observe the following procedures, and cut your instal-
lation time to a minimum.
CAUTION - TO REDUCE RISK OF FIRE AND ELECTRIC SHOCK:
1. To avoid possibility of serious injury or electrical shock, the installer must disconnect the electric circuit supplying power
to the fan outlet box prior to installing this fan. Turning the power off at the fan switch or speed control (on / off) is not an
acceptable method to prevent electrical shock.
2. To reduce the risk of fire, electric shock or personal injury, mount fan to an outlet box marked Acceptable for Fan Support
and use mounting screws provided with outlet box. (Marley Engineered Products Model 925 HANG-SAFE
TM
Outlet Box is
U.L. Listed for this purpose. U.S. patent number 4,788,383.) Installer must take adequate precautions to prevent water
entry into installation where field installed wiring will be housed.
Installation & Maintenance Instructions
SAVE THESE INSTRUCTIONS
WARNING
!