Makita EW400TR Septic System User Manual


 
3.
PREPARATIONS
FOR
STARTING
1.
Connect the suction hose.
Use a reinforced-wall or wire braided hose to
prevent suction collapse. Since the pump’s
self-priming time is directly proportional to
hose length, a short hose is recommended.
tion hose. Gravel or debris sucked
into the pump will cause serious
2.
Connect the discharge hose.
When using a fabric hose, always use a hose band to prevent the hose from
disconnecting under high pressure.
3.
Check the engine oil
level.
Engine oil is a major factor affecting engine performance and service life.
Nondetergent or vegetable oils are not recommended.
Use oil classified
“SC”
or higher grade.
If the oil level is below the fill level line on the dipstick, refill with the proper oil (see
table) to edge of the oil fuller neck.
Be sure to check the oil level on a level surface with the engine stopped.
E
Single grade
Multlgrade
Ambient
-
I I I I
I
I
0
-10
0
10
20
30
40’C
-3-