Fig. 4
Electrical outlet wiring must comply with
local building codes and other applicable
regulations to reduce the risk of fire, electrical
shock and injury to persons.
ELECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60 Hz circuit with a properly grounded
outlet is required. Preferably, the fireplace will be on a
dedicated circuit as other appliances on the same circuit
may cause the circuit breaker to trip or the fuse to blow
when the heater is in operation. The unit comes standard
with a 6 ft. (1828mm) long three wire cord, exiting the right
side of the fireplace. Plan the installation to avoid the use
of an extension cord. If an extension cord must be used,
it must be a minimum 16AWG, three wire with grounding
type plug and connector and rated not less than 2025
Watts.
A new electrical outlet can be installed inside the frame
construciton, if permitted by local codes.
Do not use this fireplace if any part of it has
been under water. Immediately call a
qualified service technician to inspect the
fireplace and replace any part of the electrical
system which has been under water.
INSTALLATION OF LOGS
1. Turn off power to the unit.
2. Remove front glass (See "Glass Removal" section).
3. The log bottom is shipped in place. No adjustment is
necessary.
Hard (Direct) Wire Connection
If desired, a qualified electrician may remove the cord
conection and wire this unit directly to the household
wiring.
Any electrical re-wiring of this appliance
must be done by a qualified electrician.
WARNING: This fireplace comes with an
optional manual circuit breaker reset beside
the On/Off switch. In case the fireplace is
not operating check the circuit breaker and
reset the button at the breaker. If the
fireplace is still not operating immediately
call a qualified service technician to inspect
the fireplace.
HE32EF / DEF33 *
* HE32EF / DEF33 is a unitized log set.
CERAMIC REFRACTORY INSTALLATION
1. Remove the glass assembly.
2. Slide refractory panels on either side of the firebox
between firebox side and the upper lintel baffle.
3. Push panels against firebox side. If desired, secure
the panels to the sides of the firebox with some
adhesive, such as silicone.
4. Replace glass frame and upper louvre panel.