Magnavox MPDR-3328CPE Indoor Fireplace User Manual


 
3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Maximum manifold pressure is 3.5 in. w.c.
(0.87 kPa) for natural gas and 10 in. w.c. (2.49
kPa) for LP/Propane gas.
Do not use these appliances if any part has been
under water. Immediately call a qualified, pro-
fessional service technician to inspect the ap-
pliance and to replace any parts of the control
system and any gas control which have been
under water.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'leau.
Test gage connections are provided on the
front of the millivolt gas control valve (identi-
fied OUT for the manifold side and IN for inlet
pressure. A ¹⁄₈" NPT test gage connection is
provided on the electronic gas control valve
adjacent to the outlet to the main burner.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled through
a remotely located optional wall switch. Sepa-
rate switches may provide independent control
for the remote controlled fireplace operation
(optional equipment).
In lieu of remote or remote wall switch opera-
tion, the appliance must be operated directly
through the controls located on the front of the
valve located within the control compartment
which is located behind the control compart-
ment access panel below the appliance front
glass enclosure panel. See
Figure 1.
Gas Controls/Control Compartment
Access
The gas controls can be found behind the
control compartment access panel.
To open the control compartment access panel,
actuate the spring-loaded magnetic catches
securing the panel, by gently depressing the
outer top corners of the panel until the catches
"pop" the door free, allowing it to swing out and
down to open.
Operation of millivolt and electronic gas con-
trol systems are different. Before lighting
and operating your appliance determine if
you have a millivolt or electronic appliance.
See
Figure 1
on page 4
for access to the
control compartment.
Millivolt appliances will be fitted with the gas
control valve shown in
Figure 3 (SIT) or Figure
4 (Honeywell) on page 4
. Appliances with
electronic systems will be fitted with the elec-
tronic valve shown in
Figure 2 on page 4
.
Familiarize yourself with the gas control valve
that your appliance uses.
The following table shows the units' orifice size
for the elevations indicated.
Electronic Models -
Electronic models have a fixed rate gas valve.
Input of electronic models is shown in the
following table:
htiwsledoMtlovilliM
evlaVsaGdetaludoM-yllaunaM
saGenaporP
seireSledoM)H/UTB(etartupnI
8233-TDPM
8233-RDPM
005,71ot000,41
0353-DPM000,02ot002,51
5304-DPM000,72ot005,12
0454-DPM000,92ot005,22
evlaVsaGetaR-dexiFhtiwsledoMcinortcelE
saGenaporPdnalarutaN
seireSledoM)H/UTB(etartupnI
8233-TDPM
8233-RDPM
005,71
0353-DPM000,02
5304-DPM000,72
0454-DPM000,92
ledoM
seireS
ezisecifirO
noitavelE
teeF
)sretem(
.taN.porP
8233-TDPM
8233-RDPM
54#hcni840.0
0054-0
)0731-0(
0353-DPM44#55#
5304-DPM73#hcni260.0
0454-DPM63#25#
Millivolt Appliances -
To light millivolt appliances refer to the detailed
lighting instructions found on
page 12 (En-
glish) and page 13
(French)
. Millivolt appli-
ance lighting instructions may also be found
on the pull-out lighting instruction labels at-
tached to the gas control valve.
WARNING: DO NOT PLACE CLOTH-
ING OR OTHER FLAMMABLE MATERI-
ALS ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.
Minimum inlet gas pressure to these appliances
is 5.0 inches water column (1.24 kPa) for natural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.
The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure test-
ing of the gas supply piping system at test
pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of ¹⁄₂ psig
(3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
Any safety guard or screen removed for ser-
vicing the appliance must be replaced prior to
operating the appliance.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the
flu with headaches, dizziness and/or nausea. If
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance
and have it serviced by a qualified profes-
sional, as it may not be operating correctly.
WARNING: FAILURE TO COMPLY WITH
THE INSTALLATION AND OPERATING IN-
STRUCTIONS PROVIDED IN THIS DOCU-
MENT WILL RESULT IN AN IMPROP-
ERLY INSTALLED AND OPERATING AP-
PLIANCE, VOIDING ITS WARRANTY. ANY
CHANGE TO THIS APPLIANCE AND/OR
ITS OPERATING CONTROLS IS DANGER-
OUS. IMPROPER INSTALLATION OR
USE OF THIS APPLIANCE CAN CAUSE
SERIOUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MON-
OXIDE POISONING.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURES. USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.