Magellan MG-6060 Home Security System User Manual


 
Paradox Magellan Systems 21
One-Touch Arming
Section [092]: Options [7] and [8]
Option [7] OFF = One-touch Regular/Force arming disabled
Option [7] ON = One-touch Regular/Force arming enabled
(default)
Option [8] OFF = One-touch Stay arming disabled
Option [8] ON = One-touch Stay arming enabled (default)
The One-touch arming features allow users to arm the system
without having to enter any access codes. To arm the system,
press and hold the appropriate key for approximately 2 seconds.
Exit Delay
Section [062]: 001 to 255 seconds; 000 = disabled; Default = 60
seconds
The exit delay determines the amount of time a user has to leave
the protected area before Magellan arms the system. The exit
delay applies to all zones (except 24Hr zones) in the system.
Program the exit delay from 001 to 255 seconds.
Bell Squawk on Arm/Disarm with Remote
Control
Section [093]: Option [3]
Option [3] OFF = Bell squawk disabled
Option [3] ON = Bell squawk enabled (default)
When option [3] is enabled (ON), the siren will squawk once
upon arming with a remote control and twice upon disarming with
a remote control.
No Exit Delay when Arming with Remote
Control
Section [093]: Option [4]
Option [4] OFF = Provides exit delay when arming with remote
control (default)
Option [4] ON = No exit delay when arming with remote control
When option [4] is enabled (ON), the console cancels the Exit
Delay (arms instantly) when the system is armed with a remote
control. When disabled, the Exit Delay timer will start when the
system is armed with a remote control.
Exit Delay Termination
Section [093]: Option [6]
Option [6] OFF = Exit delay termination feature disabled
Option [6] ON = Exit delay termination feature enabled (default)
When option [6] is enabled (ON), the console will reduce the exit
delay to 10 seconds when an Entry Delay zone (see Exit Delay
on page 21) is opened and closed during the exit delay.
Example: 15 seconds into a 45 second exit delay, an Entry Delay
zone opens and closes. The remaining 30 seconds is reduced to
10 seconds.
Follow Zone Switches to Entry Delay 2
Section [093]: Option [7]
Option [7] OFF = Follow zone triggers an alarm (default)
Option [7] ON = Follow zone follows Entry delay 2 when
opened
When option [7] is enabled (ON) and an Entry Delay 1 zone is
bypassed, an armed Follow zone that opens without an entry
delay being triggered will switch to the entry delay 2 timer.
Example: Zone 1 is an Entry Delay zone and zone 2 is a Follow
zone protecting the area where the keypad is installed. The
system is armed but zone 1 is bypassed. With option [7]
enabled, zone 2 will switch to and wait for the entry delay 2 timer
to elapse before triggering an alarm.
Closing Delinquency Timer
Section [080]: 001 to 255 days; 000 = Disabled; Default = 000
The Magellan console will verify when the system was last
armed at midnight of every day. If the last time the system was
armed is greater than the programmed Closing Delinquency
timer, the console will transmit a Closing Delinquency report
code (page 25) to the central monitoring station.
Enter a value from 001 to 255 days into section [080] to program
the Closing Delinquency timer. Enter 000 to disable the timer.