remaining days, one after the other (specific days may be skipped by
pressing the UP button to advance past them when they are flashing in the
“copy to” location). To exit the Copy feature, and return to the regular
temperature program screen, press and hold the NEXT button for more than
2 seconds. Return the Set Slide Switch to the RUN position when you are
finished.
TEMPERATURE SWING AND OFFSET SETTING: A thermostat works by
turning your heating or cooling system on and off whenever the room
temperature varies from the desired set-point temperature. The amount of
this variation is called the swing. Generally your system should cycle on
about 3 to 6 times per hour. A smaller swing number makes the system
cycle more frequently, so the room temperature is more precise and
constant. A larger swing number will make the system remain on for a
longer duration each time and decreases the number of cycles per hour.
There is only one Swing setting, and this determines the cut-in and cut-out
points for both the first and second stages (if present), in both Heat mode
and Cool mode.
NOTE: The Swing and Offset settings need to be performed in a timely
manner, as the thermostat will timeout and automatically exit these
adjustment screens after approximately 10 seconds without a button press.
TO CHANGE THE SWING SETTING: Ensure that the System Mode switch is in
the OFF position and the Set Slide switch is in the RUN position. Press and
hold the HOLD button for at least 5 seconds. The words “SET” and “SWING”
will appear in the upper right corner of the screen, along with a single
flashing digit. Use the UP/DOWN buttons to change the number value
between 1 and 9 (0.25F to 2.25F, in 0.25F degree increments). Number 1 is
the default setting. Press the NEXT button to accept the swing setting and
proceed to the OFFSET setting.
TO CHANGE THE OFFSET: After the Swing value has been accepted, the
words “SET” and “OFFSET” will be shown on the screen, along with a
flashing digit. This setting is shown as a number of degrees, and is similar
in nature to the Swing however this only effects the operation of the second
(auxiliary) heating stage, if present. The setting range for Offset is from 0 to
9 degrees. When set to 0 degrees, the second heating stage is completely
disabled while in regular Heat mode (Emergency Heat mode will still function
24
ADVANCED FEATURES: