Lopi Revere Indoor Fireplace User Manual


 
28 Listing Label
© Travis Industries 100-01165 4040806
Listing Label
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA
MODEL:
LOPI
®
REVERE (X-NT)
Report No. 028-S-44-4
SERIAL NO:
Listed Fireplace Insert for installation into a Factory-Built (Z.C.) fireplace or masonry fireplace
WARNING - DO NOT REMOVE THIS LABEL
A representative product sample of this model stove has been tested to meet UL 1482
Standards for safety. For use with solid wood fuels only. Install and use only in accordance
with the manufacturers installation and operation instructions. Check all local building
codes. DO NOT ELEVATE FIRE. Build fires directly on the firebrick. Install with or without a
direct flue connector pipe in a MASONRY FIREPLACE with facing shroud plates.
Factory-Built (Z.C.) Fireplace installations require a minimum 24” starter section directly
connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.) Fireplace chimney
must have a minimum cross-sectional area of 28.85”. The Factory-Built (Z.C.) Fireplace
damper and control must be removed, or secured in the open position. For minimum
Factory-Built (Z.C.) Fireplace firebox size, see manufacturer’s installation instructions.
Factory-Built (Z.C.) Fireplace floor protection must be 3/8” minimum non-combustible
material or equivalent, extending 16” in front of insert and 8” to both sides. A metal
deflector plate must be installed if the flue collar is not completely behind the Lintel plate
of the Factory-Built (Z.C.) Fireplace openings.
Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup
may occur rapidly. DO NOT OVERFIRE. If heater glows, you are overfiring. Do not remove
bricks or mortar from masonry fireplace. OPEN DAMPER BEFORE OPENING LOADING
DOORS! Maintain 36" front clearance to all furnishings and other combustible materials.
CLEARANCE TO COMBUSTIBLES, MASONRY FIREPLACE INSTALLATION
Minimum Clearance to Masonry Factory-Built
Combustibles and Hearth Fireplace (Z.C.) Fireplace
Requirements Installations Installations
A. 15” 30”
B. 13” 12”
C. 28.5” 12”
With Shield 20.5” N/A
D. 30.5” 24”
With Shield 22.5” N/A
Hearth Extension Front 16” 16”
Hearth Extension Sides 8” 8”
Electrical Rating:
Volts-115 Watts-21.4 Amps-1.8 HZ-60
Note: Replace glass only with 5mm Lopi
ceramic
OPTIONAL 125 CFM BLOWER PACKAGE
MANTEL
HEARTH EXTENSION
FACIA OR TRIM
INSERT
SIDEWALL
INSERT CLEARANCE DIAGRAM
AB
C
D
8
16
10850 117th Pl. N.E. Kirkland, WA 98033
Manufactured By:
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standards.
Date of Manufacture
2001 2002 2003 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec
.
0234