The purpose of this booklet is to provide assembly, installation
and operation information concerning Model AUJ-S & AUH-S
Commercial Vehicular Garage Door Operators and related
Accessory Products.
NOTICE
IT IS IMPORTANT THAT THIS INSTRUCTION MANUAL BE
READ AND UNDERSTOOD COMPLETELY BEFORE
INSTALLATION OR OPERATION IS ATTEMPTED. IT IS
INTENDED THAT THE INSTALLATION OF THIS UNIT WILL
BE DONE ONLY BY PERSONS TRAINED AND QUALIFIED
IN THE INSTALLATION, ADJUSTMENT AND SERVICE OF
COMMERCIAL OVERHEAD DOORS AND DOOR
OPERATORS AND BY QUALIFIED ELECTRICIANS.
NOTICE
THE IMPORTANT SAFEGUARDS AND INSTRUCTIONS IN
THIS MANUAL CANNOT COVER ALL POSSIBLE
CONDITIONS AND SITUATIONS WHICH MAY OCCUR
DURING ITS USE. IT MUST BE UNDERSTOOD THAT
COMMON SENSE AND CAUTION MUST BE EXERCISED
BY THE PERSON(S) INSTALLING, MAINTAINING AND
OPERATING THE EQUIPMENT DESCRIBED HEREIN. DO
NOT USE THIS EQUIPMENT FOR ANY OTHER THAN ITS
INTENDED PURPOSE - OPERATING OVERHEAD
COMMERCIAL VEHICULAR GARAGE DOORS.
STANDARD FEATURES:
Solid State Controls: The openers employ solid state
technology with advanced standard features to provide for a
complete commercial door operating system.
Switch Selectable Operating Modes: Six distinct base
operation modes can be selected by resetting the switches on the
motor control board: a standard Open, Close, Stop (B2,
momentary button push); three constant pressure modes (C2, D1,
and E2); two Timer to Close modes (T and TS). See page 17 for
complete description of the modes.
Switch Selectable Characteristic Modes: Five different
operating characteristics can be activated and/or modified
through the switches on the motor control board: Delay On
Reverse, Close Limit Delay, Mid Stop Travel, Timer to Close,
Maximum Run Timer.
Limit Switches: Driven limit switches, easily adjusted over a
wide range. The motor may be removed without affecting the
limit switch adjustments
Manual Release: Permits manual operation of the door in the
event of a power failure. The Model AUH-S is equipped with a
chain hoist to aid in manual operation.
Control Circuit: Standard three button open, close and stop.
5 Volts DC.
Connections For Auxiliary Entrapment Protection
Devices: For the ultimate in protection, terminals are provided
to connect a Linear Corp. Photo-Beam System that consists of an
emitter, Part No. 217792 and detector, Part No. 217800. This
device when connected is a monitored photo-beam system.
Additional connection terminals for a Normally Open and
Normally Closed reversing devices such as a reversing door edge
or a three wire photo-beam are provided.
Momentary Contact To Close: Standard operating mode.
Requires a photo-beam as described above or one of the Miller
Edge family of Door Edge devices as described on this page to
be properly installed on the door and connected to the
operator. See Page 12 for the entrapment protection
installation guide.
JACKSHAFT OPERATOR APPLICATIONS
Jackshaft operators are intended for commercial and industrial
use to raise or lower sectional overhead doors by chain coupling
or direct coupling to the door shaft. Jackshaft operators are
suitable where all or part of the door remains in a vertical position
when fully open such as doors with at least 18 inches of lift
clearance or full vertical lift doors. Jackshaft operators may also
be used with roll up service doors and grills when appropriately
modified at the factory to obtain the correct speeds.
A jackhaft operator DOES NOT LOCK THE DOOR IN ITS
CLOSED POSITION. However, because the cross-header
shaft is prevented by the operator from turning, the torsion
springs provide no assistance in lifting the door should an
attempt be made to raise it manually.
The jackshaft operators as described in this manual are
used in the following applications:
- Continuous Duty, Medium Cycle Commercial
installations only
- Indoor Use Only
- Up to 24 foot high doors with a maximum area of 480
square feet for 3/4 HP, 280 square feet for 1/2 HP and
200 square feet for 1/3 HP - maximum area slightly
higher for lighter doors - consult factory
- To operate in Momentary Contact To Close mode and
comply with the UL325 Entrapment Protection requirements
effective Aug. 29, 2010, the door system must include one of
the following (a, b, or c):
(a) Linear Corp. Photo-Beam System that consists of an
emitter, Part No. 217792 and detector, Part No. 217800 for
doors as described above up to 30 FT wide. See Page 13.
(b) Any Miller Edge ME, MT/MU, and CPT family of edges,
with suffix T2, must be connected to the SM-102 Edge
Module, Recognized by UL as per UL325 2010 on 08-29-
2010 for door as described above. See Page 13.
(c) A Vitector Fraba OSE 2-wire Photosystem as Recognized
by UL as per UL325 2010 on 08-29-2010 for door as
described above. See Page 13.
- The manufacturer of this operator strongly recommends
installation of one of the entrapment protection device above
and states that one is REQUIRED where any automatic,
remote or manual control is used to activate the door.
OPTIONAL FEATURES:
Digital Radio Controls: Open, Close and Stop operation.
Radio units are available to control up to 27 doors from one
transmitter
Keyless Entry System: Connection terminals provided for
hard wired or wireless keyless entry systems.
Direct Coupling (FS or FC Mount): Must be pre-ordered
from the factory. Flange couplers direct connect the operator
output shaft and the door shaft. Door shaft speed is 30 RPM
unless otherwise specified.
PRODUCT FEATURES
3