Lincoln LFC 3000 Home Security System User Manual


 
Page Number - 7
Form 403082
LFC 3000 Users Manual
Series A
Dispense Mode
Pre-Select - Free Dispense
Customer Menu
Odometer & Reg.
With the LFC 3000 you can store the odometer reading and
the license plate number of the vehicles maintained in the
garage. This information will appear on the transaction
ticket;
ENTER
Odometer & Reg.
Yes
Use Up / Down keys to select
The keypad will always ask the operator to store the
odometer and registration plate of the vehicle
corresponding to the job number.
Odometer & Reg.
No
The function will not be activated.
Customer Menu
Initial Timeout
The initial time-out is the time between the validation of the
transaction datas on the keypad and the opening of the
solenoid valve corresponding to the selected hose. Enter
the maximum number of seconds necessary before starting
the operation.
In a multi I/O system without PC, this parameter must
programmed and be the same and on each I/O.
ENTER
Initial Timeout
06
Customer Menu
Inactive Timeout
The inactive timeout is the period between the last pulse
received by the system and the closing of the solenoid. The
LFC 3000 will close the transaction if the time between 2
pulses reaches the inactive-time configured in the system.
It is visualized that the operator has started to fill the vehicle
with oil and that he has stopped the dispense before the
pre-set quantity has been reached or because he is work-
ing in the free dispense mode. When choosing this dura-
tion, bear in mind that this should be long enough for your
worker to verify the oil level on the dip stick. Enter the
maximum number of seconds needed.
Customer Menu
Warn Level
A minimum stock level must be set for each tank. All fluids
dispenses will automatically be deducted from the respective
tank stock. When the stock level in the tank reaches the warn-
ing level, a warning reordering message will automatically be
printed on the report printer.
ENTER
Use Up / Down arrow key to select the tank
Warn Level
Tank 1 = _ _ _ _
ENTER
Warn Level
_ _ _ _ 0
Enter the minimum stock level
ENTER
Warn Level
400
Customer Menu
Stop Level
In addition to the minimum level, the LCF 3000 offers the
ability to set up stop levels for each tank, preventing
dispenses of the selected product when the level in the tank
is under the stop level limit. This will prevent air to enter in
the oil line and prevent any risk of impurities entering the
line as well.
ENTER
Stop Level
Tank 1 = _ _ _ _ 0
Choose the tank you want to configure.
ENTER
New Stop Level
_ _ _ _ 0
Customer Menu
Dispense Mode
The LFC 3000 offers the possibility for the operator to
dispense oil in Pre-Select or in free dispense mode. In Pre-
select mode, the system will not authorizes any dispense
without a pre-selected quantity of fluid. In free dispense, the
system will authorize dispenses without pre-selection of any
quantity.
The system will close the transaction when the inactive
time-out has been reached.
ENTER
Use Up / Down key to select the mode.