LiftMaster LM1000A-2 Garage Door Opener User Manual


 







Emergency quick release, Automatic trolley reconnect, Trolley disconnect mode setting
Ventilation/pet opening, Safety stop and full reverse, Up: Safety stop, Automatic close (dependent on model),
Flashing light connection (dependent on model), Door-in-door switch (dependent on model)

Door Linkage: Adjustable door arm (dependent on model),
Logic Type: Solid-state microprocessor with built-in surge suppressor, Solid-state light delay (dependent on model)
Force Adjustment: Segmented - Automatic learn, Length of line cord: 1.2 m (dependent on model)
Temperature: -30 °C to +65 °C

Logic boards feature the exclusive Smart Button for programming transmitter codes to receiver memory.
RF Module: 433.92 MHz – AM Superheterodyne
Rolling Code or Billion Code decoding
Battery (Remote Control): 2 x 3 V or 1 x 3 V (94335E)
Remote control may be programmed from operator or control panel.
Remote control may be programmed to control the opener light.
Remote control may be programmed to an open/close/stop function.
2.5 minutes light timing adjustable to 1.5, 2.5, 3.5, 4.5 minutes.
Operator light may be programmed to turn on when IR beam is broken.
In order to gurantee a smooth operation, we help you to diagnose in case of a failure.
Through simple ashing signals you will know what to do quickly.

 The Protector System™ open, misaligned or an object has broken IR beam for more than 4 seconds.
 The Protector System™ wire shorted or connected backwards.
 Door or wall control button wire shorted.
 IR sensor slightly misaligned (dim or ashing sensor LED) or partially blocked.
 No RPM in the rst second of travel. Motor has stalled or the electronics did not see the
RPM signal. The unit will stop or reverse in 1 second.
 RPM caused a reversal (low force setting).
 Bad logic board (Unplug and reconnect operator).
 No passpoint detected during travel.
 Transmitter code being received.
(Operator not necessarily programmed to respond)
Install all operators to EN12453 and/or EN60335-95-2. 
 All trolley operator impact forces, force sensing, door, weight, and size ratings have been tested and veried by
TÜV-Rheinland. LiftMaster™ operators carry TÜV approval and CE marking.
All operators are HomeLink compatible.