LG Electronics NL-7005 BN Door User Manual


 
Kantooradres: Postadres:
Vlijtstraat 40 Postbus 127
NL-7005 BN Doetinchem NL-7000 AC
H.R. te Arnhem nr: 09087869 Tel: (+31) 314 376 876
E-mail: info@lagard.nl Internet: http://www.lagard.nl BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878
LG 39E Combogard EN
Revise: 1
Datum: 16-02-05
3
LA GARD Locks BV
Manual programming LG 39E Multi User
Factory Mode
(Pre-Setup-mode)
The lock maybe mounted in the factory mode. It opens when
pressing key “1” and it sends a silent alarm signal.
The advantage is that there is only 1 version storage and an
easy use during mounting.
Exit the Factory-Mode
Keep pressed the key “0” until the double signal (4-5
seconds). Now the manager code is 555555.
Code length and program selection
(6-9 digit code length is possible)
The code length and program selection are made with the
function “8” in a group of 2 digits. The first digit is the code
length and the second one is the program number.
Program 0 = Manager mode (operation with parallel code)
Program 1 = Manager mode with delay override
Program 2 = Operation with two codes
Program 3 = Two code operation with delay override
Program 4 = Manager mode with alarm
Program 5 = Manager with alarm and with delay override
Program 6 = Two code operation with alarm
Program 7 = Two code operation, alarm and delay override
Programming
(function 8)
Enter the manager code “555555” and keep pressed the
last number until the double signal is repeated (LED is on)
and enter “8”. Enter the group of 2-digits (code length and
program number) double signal and repeat the group for
confirmation (double signal).
In case of the 7-digit codes the manager code is 7x “5”.
Install (Enable) user
(function 1)
Enter manager-code and keep last digit pushed until LED
stays on. Press „1“ (double signal) and enter user-ID Nr. f.i.
„1“ (double signal). Enter user code (double signal) and to
confirm, enter the code again. Double signal and LED
extinguished.
In case a new code is not accepted (3-time-signal), this code
is too similar to an already existing code. Select new code.
NOTE: Users who are not installed in this stage will be
blocked after changing the manager code!
Program “freeze”
After changing the manager code the program is „frozen“ and
the program settings can only be changed after a reset to
Factory Mode.
Reset to Factory Mode
In case the manger code is lost or the setting of the lock has
to be changed, a reset can be executed by means of the
RESET-BOX (PN#6066). Unplug battery from the lock or
entry.
Push the "0" button for ca. 3 minutes (or leave it for
10minuts powerless) and plug the RESET-BOX in the BAT-
connection of the lock. Wait until a longer signal. (0,5 sec)
The Reset-Box requires a connected 9V-DURACELL
ALKALINE-battery.
The lock is in FACTORY MODE.
Disconnect Reset-Box and
plug battery back again. Lock opens with “1”.
Safety notice: Do not assign code to the users of no use for the time being.
Remove the codes. (Function 3 and user number)