LG Electronics NL-7005 BN Door User Manual


 
Kantooradres: Postadres:
Vlijtstraat 40 Postbus 127
NL-7005 BN Doetinchem NL-7000 AC
H.R. te Arnhem nr: 09087869 Tel: (+31) 314 376 876
E-mail: info@lagard.nl Internet: http://www.lagard.nl BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878
LG 39E Combogard EN
Revise: 1
Datum: 16-02-05
2
LA GARD Locks BV
Silent alarm:
(must be programmed)
If feature is active AND optional alarm box or SP-box is connected.
If the last digit is chosen one higher (+1) when entering the code, the lock
will open as usual (double signal), but at the same time the alarm box is
activated. Example: Combination: 471147 Alarm code: 471148
Time delay for opening:
(Must be programmed)
Time delay override:
(Must be programmed)
If feature is active:
After entering a valid code (double signal) the delay period starts, the LED
flashes red each 2-second interval.
At the end of the delay period the Open window starts, the LED flashes
each second and the lock beeps every 2 seconds.
To open the lock, a valid code has to be entered during the Open window.
If the Open window expires without the lock being opened, then the lock is
secured again with the Time delay.
Delete current delay time: press key “0”
Extend current delay times: enter valid code. The delay period will start
again.
The user ID# 9 (money carrier) can open immediately. At the operation
with two codes the ID# 9 is entered as the second code.
Power supply:
When the batteries are running low, the lock will signal for about 3
seconds while being opened. The batteries then have to be changed.
Use DURACELL ALKALINE batteries only!
The codes are stored in the lock also without power supply.
3710, 3750 and 3750K: Battery compartment is in the bottom of the entry.
3035: Open battery box (inside door) and insert new batteries.
If the batteries have not been changed in time and the tension does not
suffice to cancel the lock‘s blocking feature, a new 9V DURACELL
ALKALINE battery can be pressed onto the contacts on the entry, until
the code has been entered and the entry is rotated.
When Time Delay is programmed, use a battery clip (on general sale).
Black upper position, red lower position.
When connected to the alarm equipment through the interlock device “SP“
then the power supply is secured from this place
.
Safety notice:
Change the manager code immediately
Do not use personal data (birth date) as a code
Keep the code from unauthorised use
LED and acoustic signals:
1 x short signal enter confirmation
2 x short signal valid code entered
3 x short signal wrong code, not accepted
6 x short signal remote disable, blocked by the alarm
equipment
LED signal each 10sec. 1 flashing blocking time after a wrong tries
LED signal each 2sec. Time delay before opening is running
Alternate LED and acoustic signals Time window for opening is running
A series of triple signals, ca. 3seconds: Low battery
Still possible ca. 10 openings.
According to the battery capacity there may be also less signals
therefore the battery change should be made also in case of
double signals
Use 9V DURACELL ALKALINE batteries only!