LG Electronics LM50 2004-E1 Air Conditioner User Manual


 
70 MPS Variable Multi Split System(50Hz, R410A)
14. Installation
There should not be any heat source or steam near
the unit.
There should not be any obstacles to prevent the air
circulation.
There should be easy provision of condensate drain age.
Taking into account the noise prevention criteria,
spot the installation location
Do not install the unit near the door way.
Keep proper distance from ceiling, fence floor, walls
& other obstacles as shown in figure.
Lower than 2.3m
More than 5 cm
Higher than eye-level
More than
5 cm
More than
5 cm
14.2 Select the best location
14.2.1 Indoor Unit
Install the air conditioner in the location that satisfies the following conditions.
Wall Mounted Type
ART COOL Type
Do not have any heat or steam near the unit.
Select a place where there are no obstacles in front of the
unit.
Make sure that condensation drainage can be conve-
niently routed away.
Do not install near a doorway.
Ensure that the space around the left and right of the unit
is more than 50cm. The unit should be installed as high
on the wall as possible, allowing a minimum of 10cm from
ceiling.
Use a stud finder to locate studs to prevent unnecessary
damage to the wall.
More than 10cm
More than 50cm
More than 2m
More than 50cm