LG Electronics LA120CPO Air Conditioner User Manual


 
38 Room Air Conditioner
. Auto Operation (Electronic control mode)
The operation procedure is shown below. (Cooling & Heating Model)
If initial mode is decided, that mode is continued without the room temperature changing.
Auto Operation for Cooling
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed are decided automatically by the unit electronic control.
Setting temperature
Intake-air
temperature
Operation Mode
Over below
70
°
F76
°
F
Soft Dry
below 70
°
F
Heating
Over 76
°
F
Cooling
~
INTAKE AIR TEMP.
SETTING TEMP. +1°F
(Compressor OFF)
SETTING TEMP. -1°F
(Compressor ON)
COMPRESSOR ON OFF ON OFF
INDOOR FAN SPEED The electronic control operation
Intake-air Temperature Setting Temperature
Over 78°F77°F
Over 76°F~below 78°F Intake air -1°C
Over 72°F~below 76°F Intake air -0.5°C
Over 68°F~below 72°F Intake air temperature
below 64°F64°F
Over 64°F~below 86°F Electronic control
below 64°F64°F
over 86°F86°F
Operation Condition
When Auto Operation
initial start
Controlled by
the electronic
control
In this mode,
when pressing
the vertical air
direction control
button, vertical
louver swings up
and down
automatically.
Fan Speed Air Direction Control
When pressing room
temperature setting
button during Auto
Operation
Operation