LG Electronics LA120CPO Air Conditioner User Manual


 
Service Manual 15
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 19.6"(50cm). The
unit should be installed as high as possible on the
wall, allowing a minimum of 7.9"(20cm) from ceiling.
6. Use a stud finder to locate studs to prevent unneces-
sary damage to the wall.
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat radia-
tion from the condenser is not restricted.
2. Ensure that the space around the back and sides is
more than 11.8"(30cm). The front of the unit should
have more than 28"(70cm) of space.
3. Do not place animals and plants in the path of the
warm air.
4. Take the weight of the air conditioner into account
and select a place where noise and vibration are min-
imum.
5. Select a place where the warm air and noise from the
air conditioner do not disturb neighbors.
Select the best Location
More than
7.9"(20cm)
More than
19.6"(50cm)
More than
4.9ft(1.5m)
More than
19.6"(50cm)
CAUTION: Install the indoor unit on the wall where the height from the floor is
more than 4.9 feets(1.5 meters).
More than
11.8"(30cm)
More than
11.8"(30cm)
More than
23.6"(60cm)
More than
23.6"(60cm)
More than
28"(70cm)
Rooftop Installations
If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring
method are adequate for the unit location. Consult local codes regarding rooftop mounting.
If the outdoor unit is installed on roof structures or walls, this may result in excessive noise and vibration, and may
be also classed as non serviceable installation.
Installation