Page 3
Important Directions
1 - Keep the furnace area clear and free of combustible
material, gasoline, and other flammable vapors and liqĆ
uids. If installed in an insulated area, furnace must be
kept free of insulating material. Insulating material may
be combustible. Inspect furnace venting system to
make sure it is in place, physically sound, and without
holes, corrosion, or blockage. Inspect furnace return
air duct connection to ensure duct is sealed to the furĆ
nace and terminates outside the space containing the
furnace. Inspect the physical support of the furnace to
guarantee that it is sound without sagging, cracks or
gaps around base and it maintains seal between base
and support.
2 - DO NOT obstruct air flow to unit. Unit must receive an
unobstructed flow of combustion and ventilating air.
3 - DO NOT store chlorine or fluorine products near unit or
introduce these products into the combustion air.
These products can cause furnace corrosion.
4- DO NOT draw return air from a room where this
furnace, or any other gas appliance (ie., a water
heater), is installed. When return air is drawn from a
room, a negative pressure is created in the room. If a
gas appliance is operating in a room with negative
pressure, the flue products can be pulled back down
the vent pipe and into the room. This reverse flow of
the flue gas may result in incomplete combustion and
the formation of carbon monoxide gas. This toxic gas
might then be distributed throughout the house by
the furnace duct system.
Your furnace is a gas appliance. It is critical that the gas
supplied to the unit be completely burned to avoid the proĆ
duction of carbon monoxide gas. Complete combustion
of the gas requires, but is not limited to, correct gas presĆ
sure and gas flow rate, adequate combustion air, and
proper venting.
WARNING
Carbon monoxide gas is invisible, odorless, and
toxic.
Exposure to this gas can cause personal injury and
even death to all occupants, including pets. Any item
that is powered by or gives off heat from a combustion
process (including lawn mowers, automobiles, and fireĆ
places) has the potential to produce carbon monoxide
gas. Because of this, Lennox recommends the use of
a carbon monoxide detector in your home, even if
you do not own gas appliances. Reliable detectors
are available at reasonable retail prices. Contact your
independent Lennox dealer for more details about this
investment in your safety.
Your furnace is designed to meet standards set by nationĆ
al agencies, and to operate safely when properly installed
and maintained. However, the unit's performance can be
greatly impacted by the individual installation and the opĆ
erating environment. It is your responsibility to ensure
that this appliance is maintained. Proper maintenance is
critical for your safety and the satisfactory operation of the
product. Lennox strongly recommends annual inĆ
spection and maintenance of this appliance. Contact
your independent Lennox dealer for an inspection by a
qualified service technician.
Lighting Information and Operation
WARNING
If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury or loss of life.
BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
To place G24M furnace into operation:
G24M units are equipped with an electronic ignition
system. Do not
attempt to manually light burners on
these furnaces. Each time thermostat calls for heat, the
burner will automatically light.
Gas Valve Operation (Figures 2 and 3)
1 - STOP! Read the safety information at the beginning
of this section.
2 - Set thermostat to lowest setting. See figure 1.
THERMOSTATS
FIGURE 1
3 - Turn off all electrical power to appliance.
4 - This appliance Is equipped with an ignition device
which automatically lights the burner. Do not try to
light the burner by hand.
5 - Remove the access panel.