Adjust a setting... Configure Humidifier (skip if no humidifier is being used or if humidifier is being used and default
Basic" humidification mode is desired)
System Devices
edit
about
To adjust a setting, highlight it,
then press Edit
System
resetAll
next
back
1a
1b
edit
reset
Humidification Control Mode
current value:
back
Basic
Pre−adjustment REQUIREMENTS:
1st, the device has been installed (see Page 11).
2nd, you pressed next at the Add or Remove..." screen (see Page 11).
Configure the device as follows:
1. In the system devices" list, use the arrows (1a) to highlight System. Press edit (1b).
2. In the System" list, use the arrows (2a) to highlight Humidification Control Mode.
The current value defaults to Basic mode. Press edit (2b).
3. Touch one of the radio buttons (3a) to select the mode of humidification control;
press save (3b). (After saving, check that the current value now shows the new
selection).
4. Use arrows (4a) to highlight any red colored text in the list (e.g. select Max Humidifi-
cation Setpoint). Press edit (4b).
5. Use arrows (5a) to make changes; press save (5b). Repeat for other red settings.
You will not be able to advance to the next step until all red settings have been
removed..
6. Press the back button to return to Adjust a setting..." screen.
NOTE − If the defaults for the settings shown in red, you are not required to make any changes,
but you must go into the edit tool, and press save (5b). When all red text is gone, the back button
will appear; press it to return to the Adjust a setting..." screen.
Display Only Basic
Precision Basic Dew Point Control
Precision Dew Point
Select one
Humidification Control Mode
cancelsave 3b
3a
edit
reset
back
Max Humidification Setpoint
current value:
45
9:39 am Aug 15, 2012
please view and save all
red settings
2a
2b
System
Air Conditioner
Furnace
Thermostat
Power (120VAC) Humidifier
Max Humidification Setpoint
Range is 15 to 45
Default is 45, inc:1
cancelsave
set−to
45
5b
5a
(returns to
adjust a
setting
screen)
4b
4a
System
1st Stage Differential
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
Max Humidification Setpoint
OK/Humid Boundary
Outdoor Temperature Reading
System
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
Figure 14. Adjust a non−communicating device settingĊHUMIDIFIER