Lennox International Inc. WING Air Conditioner User Manual


 
19
COOLING
ONLY
HEAT
PUMP
(gr.) (*)
(gr.) (*)
MODEL
(gr.) (**)
(gr.) (***)
(gr.) (**)
(gr.) (***)
54
3
2,8
(gr.) (*)
(gr.) (*)
MODEL
(gr.) (**)
(gr.) (***)
(gr.) (**)
(gr.) (***)
54
3
2,8
COOLING
ONLY
HEAT
PUMP
1.650
30
2.500
30
2.600
30
2.600
55
45 45 45
3.500
105
1.775
2.500 2.800
5555
5555
2.255
30
2.350
30
3.070
30
4.950
55
45 45 45
5.300
105
2.425 2.525 3.400
55
0
5
5/0
5
0/5
5
REFRIGERANT CHARGE
(*) Refrigerant charge R-22 precharge from factory on the outdoor unit.
(**) Meter of installation line where outdoor unit is precharged+charge also to the group
(***) If line is different to meters indicated on table put more or less charge of refrigerant per meter indicated.
Charge precharge on outdoor unit
Charge per line 55gr/m x (6-5)m
=
=
5300
55
Total charge of the installation = 5355
gr
If you need to install a group WING 5CFK, with distance of line between indoor and outdoor unit of 6 meter. The
refrigerant charge R-407C needed in the installation is:
EXAMPLE:
OUTDOOR UNITS TYPE KJF-K/ KJB
OUTDOOR UNITS TIPO KCF-K/ KCB
REFRIGERANT CONNECTIONS