Lennox International Inc. R22 Heat Pump User Manual


 
1
INSTALLATION
TECHNICAL DATA
VERTICAL FLOOR SPLIT. HEAT PUMP R22
HEAT PUMP UNIT VHA 30 VHA 50
Cooling capacity W 8.150 12.895
Heating capacity W 8.150 14.070
Cooling mode power input kW 3 4,5
Heating mode power input kW 2,8 4,5
Current Cool A 14,5 7,8
Heat A 13,5 7,5
Voltage: 50 Hz V/f 230/I 400/III
Indoor U. air flow (Height) m3/h 1140 2100
Compressor Type Reciprocating Reciprocating
Sound level Indoor U. dB(A), Height, 1m 46 48
Outdoor U. dB(A), Height, 1m 58 58
Bevel coupling pipe Liquid 3/8" 3/8"
Gas 5/8" 3/4"
Dimensions Indoor U. H x L x D (mm) 1.800 x 500 x 320 1.810 x 590 x 440
Outdoor U. H x L x D (mm) 800 x 870 x 320 1.225 x 900 x 370
Net weight Indoor U. kg 40 62
Outdoor U. kg 65 90
(1) At Eurovent Conditions Cooling operation Heating operation
Indoor air 27
o
C d.b.- 19
o
C w.b. Indoor air 20
o
C d.b. - 12
o
C w.b.
Outdoor air 35
o
C w.b. - 24
o
C w.b. Outdoor air 7
o
C d.b. - 6
o