Lennox International Inc. 16L25 Furnace User Manual


 
EXTERNAL FILTER RACK CONVERSION KIT CAT# 16L23 AND 16L24)
From Right S de to Left S de Conf gurat on
A= C
FILLER PIECE_ ... --_
FRAME
HOLDING ANGLE _ -_.
SECURING SCREW
........
I
16 INCH (40.6 CM)_ I
BOTTOM HOLDING ANGLE _
Right side configuration I_ Intermediate step
f
E_> Left side configuration
To convert to left side configuration:
1 - Remove screws securing filler piece to frame. See detail A.
2 - Flip filler piece 180 degrees and secure to bottom of frame. See detail B.
3 - Remove bottom holding angle, flip 180 degrees and secure to top of frame. See detail B.
4 - Flip frame 180 degrees to give orientation as in detail C.
FIGURE 2
SECURING
SCREW _--_-_____ =
FRAME
FILLER PIECE --
HOLDING
ANGLE
EXTERNAL FILTER RACK CONVERSION (KIT CAT# 16L23 AND 16L24)
From 16 inch (40.6 cm) Filter Size to 20 inch (50.8 cm)
Left Side Orientation Shown
NOTE - THIS CONVERSION ISALSO RECOMMENDED IF
__ FILTERIS NOT INSTALLED IN RACK, BUT IS LOCATED
ELSEWHEREIN RETURNAIR DUCT.
TO convert from 16 inch (40.6 cm)
to 20 inch (50.8 cm) filter size:
1 - Remove screws securing filler piece to frame.
2 - Remove holding angle from filler piece. Discard filler piece.
_. 3- Re-secure ho d ng ang e to top of frame.
16 INCH
(40.6 CM)
FILTER
20 INCH (50.8 CM)
FILTER
FIGURE 3
Page 5