FLOOR PROTECTION
This appliance requires a non-combustible floor protection for
ember protection. If the floor protection is to be stone, tile,
brick, etc., it must be mortared or grouted to form a continu-
ous non-combustible surface. If a chimney connector extends
horizontally over the floor, protection must cover the floor under
the connector and at least 2" (51 mm) to either side.
The floor protection must extend completely beneath the
stove and to the front, sides, and rear as indicated:
USA REQUIREMENTS
16” min. to the front of the fuel door glass
4-1/2" beyond the sides of the stove body (measured to side
of stove below the projection of outer top)
0” min. to the back of the stove body
CANADA REQUIREMENTS
18” (457 mm) min. to the front of the fuel door glass
8” (203 mm) min. beyond the sides of the stove body
8” (203 mm) min. to the back of the stove body
STANDARD PARALLEL HEARTH PAD SHOWN
SELECTING A LOCATION
The design of your home and where you place your
stove will determine its value as a source of heat. A
wood stove depends primarily on air circulation (con-
vection) to disperse its heat, and therefore, a central
location is often best. There are other practical consid-
erations, which must be considered before a final selec-
tion of locations is made.
Existing Chimneys
Wood Storage
Aesthetic Considerations
Roof Design (Rafter Locations & Roof Pitch)
Room Traffic
Proximity to Combustibles
Electrical Wiring
The installation of this stove will require some research.
Once your options are determined, consult with your
local building department who will be able to give you
the necessary installation requirements for your area (Is
a building permit required, rooms where installation may
not be allowed, etc.).
WARNING: CHECK ALL LOCAL BUILDING AND
SAFETY CODES BEFORE INSTALLATION. THE IN-
STALLATION INSTRUCTIONS AND APPROPRIATE
CODE REQUIREMENTS MUST BE FOLLOWED EX-
ACTLY AND WITHOUT COMPROMISE. ALTERA-
TIONS TO THE STOVE ARE NOT ALLOWED. DO
NOT CONNECT THE STOVE TO A CHIMNEY SYS-
TEM SERVING ANOTHER STOVE, APPLIANCE, OR
ANY AIR DISTRIBUTION DUCT. FAILURE TO FOL-
LOW THESE INSTRUCTIONS WILL VOID THE
MANUFACTURERS WARRANTY.
If you plan to vent your stove into an existing masonry
chimney, have it inspected by a local fire marshal or
qualified installer. Remember that a stove's perform-
ance is heavily influenced by the chimney and its loca-
tion on the roof. An oversized flue may not provide ef-
fective draw, and a flue liner may be required (see Draft
Requirements on page 8). Consult your dealer or quali-
fied installer before final selection is made.
This stove requires pre-installation work to be com-
pleted before installation can take place. This may in-
clude modification for flue and chimney.
0" USA
8"
(
203 mm
)
Can.
4½" US A
8" (203 mm) Canada
4½" USA
8" (203 mm) Canada
16" USA
18"
(
457 mm
)
Canada