Lennox Hearth RDV40 Indoor Fireplace User Manual


 
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Facing &
Mantel -
Side View
rdv33 faCing and mantel ClearanCes
(rdv40 - add 4" to rdv33 dimensions)
Note: Hearth protection to be min. 3/8” (10mm) thick non-
combustible or equivalent, with a k factor of .84.
insert leveling
At each front and rear corner of the insert is an adjustable leg
provided to level the insert should the hearth of the fireplace
be uneven. To adjust the legs, loosen the two 5/32" allen head
screws, move the leg to the desired height, and then tighten
the screws. Repeat these steps for each adjusting leg.
RDV40
G 14”(356mm) 10”(254mm) 0”(0mm)
H 0”(0mm) 2”(21mm) 4”(102mm)
WARNING: If unit is converted to an RDV40 from an
RDV33 ensure that the clearances to combustibles are
correct for RDV40.
RDV33
G 13”(330mm) 10”(254mm) 0”(0mm)
H 0”(0mm) 2”(21mm) 4”(102mm)
E
H
F
G
J
C
L
MANTEL
TRIM
Mantel
Trim
Hearth / Floor Protection
E = From Top Facing or Mantel to Bottom of Insert -
.2 RDV40 = 35-1/2”(902mm) and RDV33 = 31-
1/2”(800mm)
F = 25-1/2" From Center of Glass Door to Side Facing or
Wall - RDV40 = 25.5”(648mm) and RDV33 = 25.5”
(648mm)
J = 10.5” (267mm) Mantel to Bottom of Insert -
.2 RDV40 = 43”(1092mm) and RDV33 = 39”(991mm)
hearth proteCtion
G = Minimum Hearth Protection from Front of Insert*
H = Vertical Distance from Insert Bottom to Combustible
Material.
Clearances to Combustibles
minimum ClearanCes to Combustibles
3"/76mm
3"/76mm
3"/76mm
1-1/2”
38mm
31-1/2”
800mm
33-1/2”
851mm
36-1/2”
927mm
39-1/2”
1003mm
ClearanCes
Figure 4
Figure 5