Lennox Hearth MN04-VDLE Indoor Fireplace User Manual


 
3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the
flu with headaches, dizziness and/or nausea. If
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance
and have it serviced by a qualified professional,
as it may not be operating correctly.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled by the
following means: the factory provided unit-
mounted ON-OFF control switch, a remotely
located optional wall switch or optional remote
control. See Figure 1.
Burn-in Period
During the first few fires of this appliance there
will be some odor due to the curing of the
paint and burning off of lubricants used in the
manufacturing process.
Depending on your use, the burn-in period may
take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED
DURING THE CURING PROCESS. THE ODOR
AND HAZE EMITTED DURING THE CURING
PROCESS CAN BE QUITE NOTICEABLE AND
MAY SET OFF A SMOKE DETECTOR.
If an optional blower is installed, Do not turn it
on during the Burn-In period.
A white film may develop on the glass front
during the first few fires as part of the curing
process. The glass should be kept clean during
the first two weeks of use to prevent the film from
baking on (making it very difficult to remove).
See Glass Cleaning on Page 4.
Table 1 shows the units' gas orifice size for
the elevations indicated.
Maximum manifold pressure is 3.5 in. w.c. (0.87
kPa) for natural gas and 10 in. w.c. (2.49 kPa)
for LP/Propane gas.
Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the control
system and any gas control which have been
under water.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil
et remplacer toute partie du système de con-
trôle et toute commande qui ont été plongés
dans l'leau.
Test gage connections are provided on the front
of the millivolt and electronic gas control valve
(identified OUT for the manifold side and IN for
inlet pressure. A 1/8" NPT test gage connection
is provided on the electronic gas control valve
adjacent to the outlet to the main burner.
Minimum inlet gas pressure to these appli-
ances is 5.0 inches water column (1.24 kPa)
for natural gas and 11 inches water column
(2.74 kPa) for propane for the purpose of input
adjustment.
Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.
The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.5 kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psig
(3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
Table 1
Figure 1
WARNING: FAILURE TO COMPLY WITH
THE INSTALLATION AND OPERATING
INSTRUCTIONS PROVIDED IN THIS
DOCUMENT WILL RESULT IN AN IM-
PROPERLY INSTALLED AND OPERATING
APPLIANCE, VOIDING ITS WARRANTY.
ANY CHANGE TO THIS APPLIANCE
AND/OR ITS OPERATING CONTROLS
IS DANGEROUS. IMPROPER INSTAL-
LATION OR USE OF THIS APPLIANCE
CAN CAUSE SERIOUS INJURY OR DEATH
FROM FIRE, BURNS, EXPLOSION OR
CARBON MONOXIDE POISONING.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURES. USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.
ledoM
.oN
ezisecifirO
noitavelE
teeF
)sretem(
.taN .porP
53VDLE 83# 35#
0054-0
)2731-0(
04VDLE 73# "260.0
54VDLE 63# 25#
Any safety guard or screen removed for ser-
vicing the appliance must be replaced prior to
operating the appliance.
Piezo Ignitor
Gas
Supply
Line
ON/OFF
Switch
ON
OFF
Shut-Off Valve
(Orientation
As Shown)
Gas Valve
Air Shutter
Adjustment Arm
Gas Line Access Plate Not Installed
At The Factory. It Is Included In
The Installation Instruction Bag.
Right Corner Post