Lennox Hearth G43UF Furnace User Manual


 
G43UF / Page 11
OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM)
37
(940)
3 (76)
71M80 Ċ 1−1/2 inch (38 mm)
69M29 Ċ 2 inch (51 mm)
See Installation Instructions for specific usage.
CONCENTRIC WALL
TERMINATION APPLICATIONS
CLAMP
(Furnished)
2 x 1-1/2 in. (51 x 38 mm) 60G77
3 x 2 in. (76 x 51 mm) 33K97
REDUCER BUSHING (Furnished)
ELBOW
(Furnished)
INTAKE AIR
EXHAUST
AIR
TERMINATION
ASSEMBLY
(Furnished)
INTAKE
AIR
EXHAUST
AIR
INTAKE
AIR
INTAKE
AIR
EXHAUST
AIR
OUTSIDE
WALL
12 (305)
Minimum
Above
Grade
12 (305)
Minimum
Above Average
Snow
Accumulation
SHEET METAL STRAP
(Clamp and sheet metal strap
must be field installed to support
the weight of the termination kit.)
FLASHING
(Not Furnished)
CLAMP
GRADE
INTAKE AIR
10-1/2
(267)
46−3/4
(1187)
4−1/2 (114)
6−1/2
(165)
(Field Supplied)
ELBOW
INTAKE AIR
EXHAUST
AIR
TERMINATION
ASSEMBLY
(Furnished)
60L46 Ċ 3 inch (76 mm)
See Installation Instructions for specific usage.
CONCENTRIC ROOF
TERMINATION APPLICATIONS
CLAMP
(Not Furnished)
15F74 − 2 inch (51 mm)
See Installation Instructions for specific usage.
NOTE Ċ EXHAUST PIPE SHOWN
12 in. (305 mm) maximum
without support
NON−DIRECT VENT APPLICATION
NOTE Ċ 12 in. (305 mm) minimum height above
average snow accumulation.
Kit Contains Enough Parts For Two Installations
8 in. (203 mm)
minimum
6 in. (152 mm)
maximum
12 in. (305 mm) maximum
without support
NOTE − 12 in. (305 mm) minimum height above
average snow accumulation.
DIRECT VENT APPLICATION
WALL ASSEMBLY TERMINATION KIT − RING KIT