Cat. No. H0367 Model Profi le 20 FS-2 Pellet Stove
Flue Size 3” (76 mm Rear)
Width, Overall 22-3/8” (568 mm)
Depth, Overall 22-3/4” (578 mm)
Depth, Overall w / 3” tee 28-1/2” (724 mm)
Height 28-5/8” (727 mm)
Floor to Rear
Flue Center 11-1/4” (286 mm)
Facing back of unit,
outside edge of left side
to center of rear
fl ue outlet center 6-1/2” (165 mm)
Floor to Rear
Outside Air Inlet 12” (305 mm)
Facing back of Unit
outside edge of right side
to center of air inlet 8 3/8” (213 mm)
Floor Protection Front and Sides: 6” (152 mm)
Requirements Back: Up to 6” (152 mm)
Standard Features Fastfi re Self Igniter
Wall Thermostat
(wire included)
Hopper Capacity 55 lbs.
Burn time 15 - 37 hours
Fuse, Control Board 5 Amp, 250 volt, 3AG
Fuse, Igniter 6 Amp, 125 volt
Heat Input (BTU’s per hour) 13,000 - 32,000 BTU / hr
Overall Effi ciency 75 - 81%
Emissions 0.4 gr / hr (varies w/size and
type of fuel) EPA exempt
Shipping Weight 215 lbs.
Room Air Blower 150 CFM; .8 Amps,
2175 rpm
Exhaust Blower 95 CFM: 1.0 Amps,
3000 rpm
Auger Motor 1.1 RPM; .4 Amps
Options Nickel or Gold Trim Kits
4” Quick Disconnect
Log Set
22-3/8"
28-5/8"
11-1/4”
6-1/2"
12"
8-¾”
8-3/8"
28 1/2"
w/clean-out tee
22 3/4"
BACK VIEW
SIDE VIEW
Note: Dimensions shown are approximations only (+/- 1/4”)
Non-combustible fl oor protection is required (see Floor Protection,
Page 4). When installed at clearances less than 6”, the fl oor protector
is only required to extend to the wall.
Fuel delivery and burn times will vary depending on size and type of fuel
used. Estimated heat input based on fuel value of 8400 BTU per lb.
Fuses are rated as fast blow
SPECIFICATIONS - PROFILE
®
20 FS-2