Storageflex RMC-LC10NG, RMC-LC20NG(F), RMC-LC30NG(F), RMC-LC10NG(T), RMC-LC20NG(T),(F), RMC-LC30NG(T),(F), RMC-LC10LP, RMC-LC20LP(F), RMC-LC30LP(F), RMC-LC10LP(T), RMC-LC20LP(T),(F), RMC-LC30LP(T),(F), RMC-LI10NG, RMC-LI18NG(F), RMC-LI30NG(F), RMC-LI06NG, RMC-LI10NG( Electric Heater User Manual


 
3
RMC-LCNG, RMC-LCLP, RMC-LING, RMC-LILP Specifications
Models
(Manual &
Thermostat)
Gas Type
Input Rating
(Btu/Hr) Variable
Regulator
Pressure
Setting
Inlet Gas Supply
Pressure
Size
of Heater
Weight
Min. Max Min. Max
RMC-LC30NG
Natural
15,000 30,000
4.0” w.c. 5.0” w.c. 11” w.c.
27”x24”x8
1/2
30 lbs.
RMC-LC20NG
10,000 20,000
19
3/8
”x22
7/8
”x8
1/2
22 lbs.
RMC-LC10NG
5,000 10,000
15
1/2
x20
7/8
x7
7/8
17 lbs.
RMC-LC30LP
LP
15,000 30,000
10” w.c. 11.0” w.c. 14.0” w.c.
27”
x24”x8
1/2
30 lbs.
RMC-LC20LP
10,000 20,000
19
3/8
”x22
7/8
”x8
1/2
22 lbs.
RMC-LC10LP
5,000 10,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI30NG
Natural
6,400 30,000
27”x24”x8
1/2
30 lbs.
RMC-LI18NG
6,400 18,000
19
3/8
”x22
7/8
”x8
1/2
22 lbs.
RMC-LI10NG
5,500 10,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI06NG
- 6,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI30LP
LP
6,400 30,000
10” w.c. 11.0” w.c. 14.0” w.c.
27”x24”x8
1/2
30 lbs.
RMC-LI18LP
6,400 18,00
19
3/8
”x22
7/
8
”x8
1/2
22 lbs.
RMC-LI10LP
5,500 10,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI06LP
- 6,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
NOTE: For altitude above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.
DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET
LOCAL CODES
Install and use heater with care. Follow all local codes. In the
absence of local codes,
use the la
test edition of the National
Fuel Gas Code
ANSI Z223.2,
also kno
wn as NFP
A54.
Available from:
American Na
tional
Na
tional F
ire Protection
Standards Institute,
Inc.
Associa
tion,
Inc.
1430 Broadway
Batterymarch Park
New
Y
ork,
NY 10018
Quinc
y, MA 02269
RMC-LC30 / RMC-LC20 / RMC-LC10
RMC-LI30 / RMC-LI18 / RMC-LI10 / RMC-LI06
Certified to ANSI Z21.11.2b-2004 Unvented Heaters
This heater has a pilot with an Oxygen Depletion Sensor Shut-
off system (ODS).
The ODS pilot is a required fea
ture for vent-
free hea
ters.
The ODS pilot shuts off the hea
ter if the normal air
oxygen content is reduced belo
w 18%.
This hea
ter has a piezo ignitor
.
This system requires no ma
tch
-
es,
ba
tteries or other electrical sources to light the heater.
PRODUCT FEATURES
SAFETY DEVICE
PIEZO IGNITION SYSTEM