Kyocera SD 6-35 Water Pump User Manual


 
Solar Water Pumping Products Catalog
NOTE:
1. SD series systems require a CD 300 Pump Controller to provide the performance as shown.
2. Single,12 Volt module systems require CD 300 Pump Controller to operate at full power.
3. Systems using 2 solar modules should be wired with the solar modules in series.
4. Systems using 4 modules or more should by wired series/parallel. Modules should be connected first in strings of 2 modules in series.
These strings should then be paralleled to achieve the required power.
*For approximation purposes only.For more accurate sizing,see sizing software at www.kyocerasolar.com/products/waterpump.htm
200
150
100
50
500
2000
3000
4000
5000
6000
LITERS PER DAY
1583
1451
1319
1187
1055
923
792
660
528
396
264
132
0
GALLONS PER DAY
2 KC40 / 1 KC80
2 KC60 / 1 KC120
2 KC80
2 KC50
2 KC70
4 KC50
2-3
4-5
5-6
6-7
7-8
1000
30m (98 f30m (98 ft)
25m (82 f25m (82 ft)
20m (66 f20m (66 ft)
15m (49 f15m (49 ft)
10m (33 f10m (33 ft)
5m (16 f5m (16 ft)
0m ( 0 f0m ( 0 ft)
35m (115 f35m (115 ft)
SOLAR ARRAY WATTAGE (NAMEPLATE RATING)
1 KC40
1 KC50
1 KC60
2 KC70
SD 6-35 PERFORMANCE GRAPH
TOTAL
DYNAMIC
HEAD
SUN
HOURS
ON TILT
3-4
30m (98 ft)
25m (82 ft)
20m (66 ft)
15m (49 ft)
10m (33 ft)
5m (16 ft)
0m ( 0 ft)
35m (115 ft)
SD Pump Sizing 13