KitchenAid 8302472A Air Conditioner User Manual


 
8.Using 2 or more people, remove
cardboard or hardboard from under range.
7
9. Attach the backguard or island trim
as required for your installation.
Attachment screws are in the literature
package.
10.Slide range completely back so
anti-tip bracket is over rear brace of
range.
11.Make gas connection. Assemble
flexible connector from gas supply pipe
to pressure regulator located in the
middle front of the range. Apply pipe-
joint compound made for use with L.P.
gas to the smaller thread ends of the
flexible connector adapters. Attach one
adapter to the pressure regulator elbow
and the other adapter to the gas shutoff
valve. Tighten both adapters.
13.Leak testing of the appliance
shall be conducted according to the
following instructions:
Test all connections using an approved
non-corrosive leak-detection solution.
Bubbles will show a leak. Correct any
leak found.
14.Put a burner cap on each burner
base. Place burner grates over burner
bases and caps.
15.Reconnect power. “PF” should
appear in the clock displays. (Refer to
your Use and Care Guide for instructions
on using the electronic control.)
12.Open manual shutoff valve in
gas supply line. Wait a few minutes for
gas to move through the line.
attaching the
backguard
attaching the
island trim
center hole
not used
3 front screws
(4 rear screws required
but not shown)
use pipe-joint
compound
flexible
connector
1/2" flare
union adapter
manual gas
shutoff valve
1/2" to 3/4"
gas pipe
a 1/2" male pipe thread is needed for connection
to pressure regulator female pipe threads
regulator
burner cap
burner
base
ignitor
electrode
gas tube
opening
to range
shutoff valve
open” position
gas supply line