•
Permanent independent smoke and carbon monoxide sensors
.
• Smoke alarm takes precedence when both smoke and car-
bon monoxide are present.
• Alarm/Voice message warning system that alerts you of the
following conditions in the manner described below, thus
eliminating any confusion over which alarm is sounding:
o FIRE: The alarm/voice pattern is three long alarm beeps fol-
lowed by the verbal warning message “FIRE! FIRE!”. This
pattern is repeated until the smoke is eliminated. The red
LED light will flash while in alarm/voice mode.
o CARBON MONOXIDE: The alarm/voice pattern is four short
alarm beeps followed by the verbal warning message
“WARNING! CARBON MONOXIDE!”. After four minutes
the alarm/voice pattern will sound once every minute until
the unit is reset, or the CO eliminated. The red LED light
will flash while in alarm/voice mode.
o LOW BATTERY: When the batteries are low and need
replacing the red LED light will flash and the unit will
“chirp” one time, followed by the warning message
“LOW BATTERY”. This cycle will occur once every minute
for the first hour. After the first hour the red LED light will
continue to flash every minute accompanied by the
“chirp” only sound. The voice message “LOW BATTERY”
will sound once every fifteen minutes during the “chirp”
only cycle. This will continue for at least seven days.
• Voice Message System that alerts user to the following con-
ditions:
o System announces “HUSH MODE ACTIVATED” when the
unit is first put into HUSH Mode.
o System announces “HUSH MODE CANCELLED” when unit
resumes normal operation after Hush Mode has been can-
celled.
o System announces “CARBON MONOXIDE PREVIOUSLY
DETECTED” when the unit has detected CO concentra-
tions of 100 ppm or higher.
o System announces “PUSH TEST BUTTON” when the unit is
powered up, reminding user to activate the Test Button.
• One “chirp” every 30 seconds is an indication that the alarm
is malfunctioning. If this occurs call the Consumer Hotline at
1-800-880-6788.
4
Features