21
Gold Peak 1604A. These batteries can be purchased at
your local retailer.
WARNING! Use only the batteries specified. Use of differ-
ent batteries may have a detrimental effect on the
Smoke/CO alarm. A good safety measure is to replace the
battery at least once a year, or at the same time you
change your clocks for daylight saving time.
Alarm ReplacementAlarm Replacement
Seven years after initial power-up, this unit will “chirp”
twice every 30 seconds to indicate that it is time to replace
the alarm. A label has been provided on the side of the
alarm that has “Replace by” printed on it. Write the replace
by date on the label. The date written on the label should
be seven (7) years after the alarm was initially powered.
This alarm does have end of life Hush
®
which allows you to
silence the trouble chirp for two days giving you exrtra time
to replace the unit at a more convenient time. To activate,
press the test/reset button. While in the End of Life Hush
®
mode, will still detect CO and Smoke. This feature can only
be used for 30 days from the time the unit first indicates
end of life. At the end of the 30 day period the alarm can-
not be hushed and must be replaced immediately.
REPLACE IMMEDIATELY!
General MaintenceGeneral Maintenance
To keep your Smoke/CO Alarm in good working order,
please follow these simple steps:
Verify unit alarm, lights and battery operation by pushing
the test/reset button once a week.
Clean your alarm monthly using compressed air or a vac-
uum cleaner hose and vacuuming or blowing air through
the openings around the perimeter of the alarm. If clean-
ing does not restore your alarm to normal operation the
alarm should be replaced.
REINSTALL IMMEDIATELY AFTER CLEANING AND THEN TEST
USING THE TEST/RESET BUTTON! IF TAMPER RESIST FEA-
TURE HAS BEEN ACTIVATED, REFER TO TAMPER RESIST
General Maintenance