Kenmore 78189 Air Conditioner User Manual


 
Installation
.
See Figure9. Place bubble level between indoor silt
and outdoor end of support bracket. Turn adjusting
foot on support until level tilts ¼ bubble toward
outdoor side.
NOTE: Adjustingsupportbracket for ¼ bubble outdoor
slope shouldresult in ¼" backward slope on
installed air conditioner, required for proper water
(condensate) drainage.
5. See Figure 10. Place air conditioner inwindow,
centered over support bracket, with bottomrail on
case seated in gap between support bracket and
rear of indoorsill. Lower indoor sash to fit intoair
conditionertop rail.
I CAUTION I
To avoid risk of personal injury, property damage, or
damage to air conditioner if unit falls, hold air condi-
tioner securely in place until indoor window sash is
securely seated in top rail on outer case.
Figure 10. Placing Air Conditioner inWindow
1. Indoor sash
2. Top rail
3. Window sill gasket
4. Bottom rail
5. Support bracket
6. Level
6 1
2
.
Use carpenters' level and ensure installed air
conditioner slopes approximately ¼" toward outdoor
side. If necessary, remove unitfrom window and
turn adjusting foot to obtain proper slope.
.
See Figure 11.Position sash bracket (Item E) on top
of indoorsash, flush with outdoor sash. Secure
bracket to outside sash using %" hex-head screw
(Item D). Drill I/e"pilot holeto make screw easier to
install.
I CAUTION I
To prevent damage towindow locking or lifting
mechanisms from impropedy placed sash bracket
screw, inspectwindow carefully before ddlling or
installing screw in sash.
Figure 11. Installing Sash Bracket
1. Indoor sash
2. Sash bracket
3. Sash bracket screw
3
o
,
2.
See figure 12. Expand right side curtain on air
conditioner untilcurtain istight against window
frame. With curtain tight against frame, find top hole
and mark location on indoor sash. Drill t/8"pilot hole
into window sash, and secure curtain to sash using
Phillips screw (Item F). Repeat for left side curtain.
Figure 12. Securing Side Curtain
Indoor sash
Side curtain