Kenmore 625.38556 Water System User Manual


 
NOTE: If you ran the red reverse osmosis drain tubing
directly to a remote drain point, disregard steps 5 and 6
and refer to instructions on page 10.
6. Mount the faucet body on to the faucet base, 1/4 turn.
FAUCET ELECTRONICS
The RO system will monitor the total product flow of
the unit and also length of time the filters have been
installed. The faucet base has an indicator light that
flashes to inform you of the status of the RO membrane
and filters.
Green - RO membrane and filters are good.
BLUE
3/8" quick connect
fitting for the blue tube
BLACK TUBE
3/8" barb fitting
for the black tube
UBE
1/4" barb fitting
for the red tube
Amber - Warning, filters need replacing. Filters need
replacing, when water has been drawn, after 6 months
time (or 650 gallons have been used).
Figure 14
Red - RO membrane needs to be replaced.
INSTALL BATTERY
When the coin battery is first applied at initial start up,
the LED indicator light will flash in a red, amber, green
sequence. All timers and counters are reset to zero. in
order to reset the time and gallon count feature, push the
the button on the PWA and hold until the LED flashes
and release. The battery needs to be replaced at the time
of filter replacement. Use only lithium batteries (CR 2032
or equivalent). Improper placement of battery could
damage electronics. Use care when inserting the battery
to align it correctly on PWA with the proper polarity. See
Figure 15.
PWA board
Battery /
Reset button
Figure 15
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
13