Kenmore 625.38306 Water System User Manual


 
CHECKLIST TO HELP YOU SAVE MONEY
Ifyour water softener fails to work, make the following easy checks. Often, you willfind what is wrong yourself and
you won't have to call and wait for service. If you do not find anything wrong while making the checks, and your sof-
tener still does not work, call your Sears Service Department.
1.Also read ERROR CODE.
2. If an error code is not displayed, press and hold the SELECT button until the display changes. Then, press the
SELECT button again and hold until a flashing model code appears. For Model No. 625.383060 it must show
S 25. If any other number shows, the face plate computer is working on incorrect input and would probably be the
cause of the problem. To set the correct code, press either the UP or DOWN button. When correct model code
(S 25) shows, press SELECT to return a flashing 12:00 AM display. Reset the present time, hardness number,
etc.
PROBLEM CAUSE CORRECTION
No soft water No salt (or salt bridged) in the storage tank
Transformer unplugged at the watt outlet, or
power cable leads loose from the electronic
board, fuse blown, circuit breaker popped, or
circuit switched off.
Manual bypass valve(s) in bypass position
Dirty, plugged or damaged nozzle venturi
Valve drain hose plugged or restricted
Water hard sometimes Hardness number setting too low
Using hot water when softener is regenerat-
ing
Increase in the grains of hardness in your
water supply
Brine tank flooded Restricted drain line
Plugged or dirty nozzle & venturi
Valve rotor-disc & seals
Restricted drain line
Salty tasting water
immediately after
regeneration
Add salt, see page 22, or break the salt bridge,
see page 29. Press REGENERATION button
and hold to start a regeneration, see page 23.
Check for loss of power due to any of these
and correct. With the power back on, look at
the time display and read PROGRAM MEMO-
RY, see page 24.
Look at Fig. 18 & 19 on page 15. Move the
stem in a single valve to service. In a 3-valve
bypass, open the inlet and outlet valve, and be
sure to fully close the bypass valve.
Take apart and clean or replace damaged
parts, see page 29.
The drain hose must not have kinks, sharp
bends, or be raised too high above the soften-
er, see page 14.
Press and release the SELECT button until
HARDNESS shows in the display. Read the
hardness number in the display and be sure
the same grains per gallon number is shown
as on your water analysis report. See page 19
to reset. Press and release the SELECT button
until the present time shows in the display.
Avoid using hot water during this time because
the water heater refills with hard water, see
Automatic Bypass, page 27.
Ask your Sears retail store for a new water
analysis. Then make a new hardness number
setting, page 19.
Check for kinks, bends or obstructions, see
page 14.
Take apart and clean or replace damaged
parts, see page 29.
Check for scratches or grooves, replace if
needed.
Check for kinks, bends or obstructions, see
page 14.
Questions? Call The Kenmore Water Line 1-800-426-9345