Kenmore 580.75281 Air Conditioner User Manual


 
OBSERVEALL LOCALCODESANDORDINANCES.
DONOT,UNDERANYCIRCUMSTANCES,REMOVE
THE POWERSUPPLYCORDGROUNDPRONG.
ELECTRICALGROUNDISREQUIREDONTHIS
APPLIANCE.
For230/208volt 60 Hz,AC only, 15Afused and
properlygroundedelectricalsupply isrequired.A time
delayfuseor time delaycircuitbreakeris
recommended.Usea dedicatedcircuit,servingonly
thisappliance.
DONOT USEAN EXTENSIONCORD.
RECOMMENDEDGROUNDINGMETHOD
Foryourpersonalsafety,thisappliancemustbegrounded.
Thisappliancehasa powersupplycordwitha 3-prong
groundingplug.Tominimizepossibleshockhazard,the
cordmustbepluggedintoa matinggroundingtypewall
receptacleandgroundedinaccordancewiththeNational
ElectricalCode(ANSl/NFPA70)latesteditionandalllocal
codesandordinances.If amatingwallreceptacleisnot
available,itisthe personalresponsibilityandobligationof
thecustomertohavea properlygrounded3-prongwall
receptacleinstalledbya qualifiedelectrician.
115V~ 230V~
NOTE: The shape may be differentaccording to its model.
Powercord may include a current interrupter
device. Atest and reset button is provided on the
plug case. The deviceshould be tested on a
periodic basis by firstpressing the TEST button
and thenthe RESET button. Ifthe TEST button
does nottrip or if the RESET buttonwill not stay
engaged, discontinue use of the air conditioner and
contact a qualified servicetechnician.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
You can choose between two methods below according to your window sill shape and preference.
USING SLIT "A"
Fasten the stopper using 2 screw holes, and lead
out the power cord through slit "A".
USING SLIT "B"
Fasten the stopper using left screw hole, and rotate
properly to lead the power cord out through slit "B".
! _
Power Cord _
-4-