Kenmore 153.332318 Water Heater User Manual


 
Safety Precautions
a, WARNING
The water heater with draft hood installed must be prop-
erly vented to a chimney which terminates outdoors.
Never operate the water heater unlessit isvented to the I
I outdoors and has adequate air supply to avoid risks of_
I improper operation, explosionor asphyxiation. I
&WARNING
Minimum dearences between the water heater and com-
bustible or non-combustible construction are I" at the
sidesand rear, 4" at the front, and 6" from the vent pipe.
Clearance from the top of the jacket is 18" on most mod-
els. Note that a lesserdimension may be allowed on some
models. Refer to the label on the water heater adjacent to
the _as control valve for all clearances.
A CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of
the water heater must be accomplished in sucha manner
that if the tank or any connections should leak, the flow of
water will not causedamage to the structure. When such
locations cannot be avoided, a suitable drain pan should
be installed under the water heater. Drain pans are avail-
able at your local Sears store. Such a drain pan must be
not greater than I _ inchesdeep, have a minimum length
and width of at least 2 inches greater than the water
heater dimensions and must be piped to an adequate
!drain. The pan must not restrict combustion air flow.
IUnder no circumstances is the manufacturer or Sears to i
be held liable for any water damage in connection with
Ithis water heater.
&WARNING I
Do not use this appliance if any part of it has been under
water. Immediately call a Sears Service Technician to
inspect the appliance and to replace the gascontrol or any
_artof the burner systemwh ch hasbeen under water.
_" WARNING
HYDROGEN GAS: Hydrogen gascan be producedin a hot
water system that has not been used for a long period of
time (generally two weeks or more). Hydrogen gas is
extremely flammable and explosive. To prevent the possi-
bility of injury under these conditions, we recommend the
hot water faucet be opened for several minutes at the
kitchen sink before any electrical appliances which are
connected to the hot water systemare used(such asa dis-
hwasher or washing machine). If'hydrogen gas is present,
there will probably be an unusual sound similar to air
escaping through the pipe as the hot water faucet is
opened. There must be no smoking or open flame near
Ithe faucet at the time it isopen.
A, WARNING
INSULATING JACKETS: When installing an external
water heater insulation iacket on agaswater heater:
DO NOT coverthe temperature-pressure relief valve.
DO NOT put insulation over any part of the top of the
gaswater heater,
DO NOT put insulation over the gascontrol valve or gas
control valve/burner cover, or any access areas to the
burner.
DO NOT let insulation around the gas water heater to
get within 8 inches of the floor (air must get to the
burner).
DO NOT cover or remove operating instructions, and
safety related warning labelsand materials affixed to the
water heater.
Failure to heed this will result in the possibilityof a fire or
explosion.