Kenmore 153.332318 Water Heater User Manual


 
Installation Instructions (cont'd)
Filling the Water Heater
_, CAUTION I
Never usethis water heater unlessit iscompletelyfilledwith
water. Toprevent damageto the tank, the tank must befilledI
with water. Water must flow from the hot water faucet
beforeturn ng ON gasto the water heater.
For properventing in certain installations,a larger diameter vent
pipe may be necessary. Due to great variances in installations,
unforeseeableby the manufacturer of the water heater, you must
consult your gas company to aid you in determining the proper
venting foryourwater heater fromthe vent tablesin the latestedi-
tion of the National FuelGas Code ANSI Z223.1, alsoreferredto
asNFPA 54.
To fill the water heater with water:
Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is on the lower front of
the water heater.
Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water heater is in use.
To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run
until a constant flow is obtained. This will let air out of the
water heater and the piping.
Check allnew water piping for leaks. Repairas needed.
Venting
_,WARNING
VENT DAMPERS - Any vent damper,whether it isoperated
thermally or otherwisemust beremoved if itsuseinhibitsprop-
erdraftingofthe water heater.
Thermally Operated Vent Dampers: Gas-firedwater heaters
havingthermal efficiencyin excessof80%may producea rela-
tivelylowfluegastemperature.Suchtemperaturesmaynot be
high enough to properly open thermally operated vent
dampers. Thiswouldcausespillage of fiuegasesand maycause
carbon monoxide poisoning.
Ventdampers must bearevidenceofcertificationascomplying
with the latest edition of American National StandardANSI
Z21.68 (ANSi Z21.66 & 67, respectively,coverelectricallyand
mechanicallyactuatedventdampers).Beforeinstallationofany
vent damper,consultyourlocalSearsServiceCenter or the gas
utilityfor furtherinformation.
_ WARNING
To insure proper venting of this gas-firedwater heater, the
correct vent pipe diameter must be utilized.Any additionsor
deletionsofother gasappliancesona common vent with this
water heater may adverselyaffectthe operation of the water
heater. Consultthe localSearsService Center or gasutility if
any suchchangesare planned.
Check the venting system for signs of obstruction or deterioration
and replace if needed.
The combustion and ventilation airflow must not be obstructed.
AWARNING I
Obstructedor deterioratedvent systemsmaypresentaseriousI
healthriskor asphyxiation. [
Place the dra_ hood legs in the receiving holes on the top of
the water heater. The legs will snap in the holes to give a tight
fit.
Place the vent pipe over the draft hood. With the vent pipe
in position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal ;crew.
DRAFT HOOD _ VENT ] I
[SCRE___I DRAFT HOOD
f
VENT TO OUTDOORS
DRAFT HO_ ,ORCHIHNEV
AWARNING J
The water heater with draft hood installedmust be properlyJ
ventedto a chimneywhich terminates outtioor_ Never oper-I
_e the vraterheater unlessit k ventodte the ootdonrsandhasI
adequateair supplyto avoidrisksof improperoperation,explo-I
sionor asphyxiation. ]
AWARNING
The vent pipe from the water heater must be nolessthan the
diameter of the draft hood outlet on the water heater, and
_€_t-tslopeupward to the chimneyat least '/4inch per linear
13