Kenmore 153.330401 Water Heater User Manual


 
Troubleshooting Guide (cont'd)
Leakage Checkpoints
Use this guide to check a "Leaking"water heater. Many suspect-
-ed "Leakers" arenot leaking tanks.Often the source of the water
can be found and corrected.
If you are not thoroughly familiar with your local gas codes,
your water heater, and safety ptacdces, contact the
Center to check the water heater.
_,CAUTION
Read this manual fi_ checkingthe water
heater make sure the gas supply has been turned
J"OFF", and never turn the gas"ON" before the tank isJ
I completely full ofwater. I
ACAUTION
N..ev.erusethis water heater unlessit iscompletely filled
with water. To prevent damage to the tank, the tank i
must befilled with water; Water must flow from the hot
water faucet before turning "ON" gas to the water
I heater" i " I
O Water at the draft hood is water vapor which has
condensed out of the combustion products. This is caused
by aproblem in the vent. Contact the SearsService Center.
O *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
O'The primary anode rod fitting may be leaking.
O Small amounts of water from the temperature-pressure
relief valve may be due to thermal expansion or high
water pressure in your area,
o'The temperature-pressure relief valve may be leaking at
the tank fitting.
O Water from a drain valve may be due to the valve opened
slightly.
O'The drain valve may be leaking at the tank fitting.
O Combustion product_ contain water vapor which can
condense on the cooler surfaces of the tank. Droplets
form and drip into the fire or run on the floor. This is
common at the time ofstartup after installation and when
incoming water is cold.
O
Water in the water heater bottom or on the floor may be
from condensation, loose connections, or the relief valve.
DO NOT replace the water beater until a full inspection
of all possible water sources is made and necessary
corrective steps taken. Leakage from other appliances,
water lines, or ground seepage should also be checked.
NOTE: To check where threaded portion enters tank,
insert cotton swab between jacket opening and fitting.
If cotton is wet, follow "Draining" instructions in the
"Service and Adjustment" section and then remove
fitting. Put pipe dope or teflon tape on the threads
and replace. Then follow "Filling the Water Heater"
instructions in the Installation Instructions section.