Kenmore 153.320690 HT 66 GAL Water Heater User Manual


 
Installation Instructions (cont'd)
Installation Checklist
Whether or not the element conversion is made, the model
rating plate must be marked. Using a hard point ink I_en,
check the appropriate block within the model rating plate,
which is located adjacent to the lower accesspanel.
Is the fuse or circuit breaker size correct asshown in the chart
in the "ProductSpecifications" section?
Are the wires from the circuit breaker or fuse service to the
water heater's junction box on the correct wire size (gauge) as
shown in the chart in the "Product Specifications" section?
Is the new temperature-pressure relief valve properly
installed, andpiped to an adequate drain? See "Temperature-
Pressure Relief Valve" section.
Is the water heater completely filled with water? See "Filling
the Water Heater" instructions in the "Installation
Instructions section.
Will a water leak damage anything? See _Facts to Consider
About the Location" section.
Are the cold and hot water lines connected to the water heater
cor_tly? See "Water Piping" instructions in the "Installation
Instructions sect on.
Is there adequate clearance for maintenance around the water
heater?
Do you need to call your electric company to check your
wiring?
HOT COLD
6 "AIR GAP
FLOOR DRAIN
MODEL RATING PLATE